欢迎登录材料期刊网
S.Y.Hu Collge of Mechanical Engineering , China Agriculture University (East Campus) , Beijing 100083 , China
金属学报(英文版)
The comparison study of the relations between the hardness, wear capacity and heat treatment temperature of the electroless nickel deposition with the electroplating deposits of chromium were conducted .The results showed that the hardness and wear capacity of the electroplate technology were superior than that of electroless in general cases, but with the raising of the heat treatment temperature, the hardness and wear capacity of the samples treated by electroless deposition technology were superior obviously than that of electroplate.
关键词: electroless nickel deposition , null , null