金属学报(英文版)
A 2D full cell thermo-electric model of 160kA drained cell was set up using finite
element code to calculate its freeze profile, then the drained cell model was modified
according to the freeze profile computed and its heat balance was calculated. Compared
with that of a 160kA conventional Hall-Heroult cell (H-H cell), though the melts volume of the drained cell reduced greatly, the whole heat loss from it didn't drop down
apparently, and an analysis was presented in the paper. On the other hand, the anode-
cathode distance (ACD) of a drained cell was much less than that of a H-H cell, so
the voltage drop on it and heat produced decreased too, steps should be taken to keep
a workable heat balance on a drained cell.