C.Y. Li1)
,
H.Q. Yuan2)
,
F.X. Meng3) and Z. Zhou4) 1) Institute of Liaoning Technology
,
Jinzhou 121001
,
China 2) Northeastern University
,
Shenyang 10006
,
China 3) Shenyang University
,
Shenyang 110044
,
China 4) Xincheng Rare Earth Magnetostrictive Materials Ltd.
,
Dashiqiao 115100
,
China
金属学报(英文版)
The physical modelanditsequivalentcircuitoftestapparatusissetup by meansofimpedanceanalysis method. The magnetostriction coefficient, magnetomechanicalcoupling coefficient,frequency and anti- frequency of TbxDy1 - xFe2 - z(0 27 ≤x ≤0 3 ,0 ≤z ≤0 1) rod are measured. Somecoupling problems with mechanicalstress and electromagnetic field such as flux leakage in magnetic path are discussed. The comparing calculated with tested resultsshowsthe accuracyof measurementand thesimplification of model.