ZHENG Xiao-fei
,
KANG Yong-lin
,
MENG De-liang
,
AN Shou-yong
,
XIA Dian-xiu
钢铁研究学报(英文版)
The effect of cooling (laminar cooling) start temperature on the phase constitution was analyzed by quantitative metallography. The martensite/austenite (M/A) island distribution was fixed by colour metallography. The strength and uniform elongation of the steels were tested with quasi-static tensile testing machine. The in-coordinate deformation of the soft and hard phases was analyzed using FEM. The results indicate that when the cooling start temperature is 690 ℃, the mechanical properties are the best, meeting the requirements of X80 high deformability pipeline steel.
关键词:
high deformability pipeline steel
,
cooling start temperature
,
carbon diffusion
,
in-coordinate deformation
,
M/A island
刘守平
,
周上祺
,
王佳眉
,
任勤
腐蚀学报(英文)
用金相显微镜、扫描电镜、X射线衍射仪和X射线能谱仪对天然气井油管悬挂器腐蚀失效进行了检测分析,并对天然气井油管悬挂器用35CrMo钢进行了盐雾试验,结果表明,天然气中的水和CO2是引起腐蚀的主要介质,腐蚀产物主要是FeCO3,高速天然气冲刷和钢中的非金属夹杂加剧了腐蚀的速度.
CORROSION FAILURE ANALYSIS OF AN OIL TUBE USED IN NATURAL GAS WELL
LIU Shou-ping,ZHOU Shang-qi,WANG Jia-mei,REN Qin
Chongqing University
A failed oil tube used in natural gas well was examined by optical microscope,scanning electron microscope ,X-ray diffractometer and X-ray spectrometer.Corrosion behavior of 35CrMo steel samples of the oil tube were investigated by means of salt spray tests in the laboratory.The results show that CO2 and H2O are primary factors in the corrosion of oil tube.The corrosion product is FeCO3,non-metallic inclusions in the steel and erosion of natural gas fluid played an important role in accelerating the corrosion.
oil tube;
natural gas well;
35CrMo steel;
failure analysis;
corrosion
关键词:
悬挂器
,
null
,
null
,
null