欢迎登录材料期刊网

材料期刊网

高级检索

  • 论文(323)
  • 图书()
  • 专利()
  • 新闻()

EFFECT OF MAGNETIC FIELD ON CALCITONIN GENE-RELATED PEPTIDE IN PERIODONTAL LIG AMENTS OF RATS

X. Chang , K. Qin and Y.L.Lu Orthodontic Department of Stomatology College , China Medical University , Sheny ang 110001 , China

金属学报(英文版)

proach change of CGRP with time in periodontal ligaments of rats in magnetic field, maxillae of 28 Wistar rats of 6 7 weeks were placed in magnetic fields of permanent magnets Nd 2 Fe 4 B. Changes of CGRP with t ime in maxillary periodontal ligaments of the rats were studied by immunohistochemistry. The result showed that: magnetic field had dynamic effect and some promotional effect on recove?E F F E C T O F M A G N E T I C F I E L D O N C A L C I T O N I N G E N E- R E L A T E D P E P T I D E I N P E R I O D O N T A L L I G A M E N T S O F R A T S X. Chang , K. Qin and Y. L. Lu Orthodontic Department of Stomatology College , China Medical University , Shenyang 110001 , China Manuscript received 24 June 1999 In order to approach change of C G R P with tim e in periodontal liga m ents of rats in m agneticfield , m axillae of 28 Wistar rats of 6 7 weeks w ere placed in m agnetic fields of per m anentm agnets Nd 2 Fe4 B. Changes of C G R P with tim e in m axillary periodontal liga ments of therats were stu died by i m m unohistoche mistry . The result sho wed that : m agnetic field had dy na m ic effect an d so m e pro motional effect on recovering and reconstruction of the periodontaltissues in it . This provided a better theoretical evidence for clinical use of per m anent m agnets .

关键词: per m anent m agnet Nd 2 Fe4 B , null , null , null

Nickel-free stainless steel for medical applications

材料科学技术(英)

BIOSS4 steel is essentially a nickel-free austenitic stainless steel developed by the Institute of Metal Research, Chinese Academy of Sciences, in response to nickel allergy problems associated with nickel-containing stainless steels that are widely used in medical applications. The high nitrogen content of this steel effectively maintains the austenitic stability and also contributes to the high levels of corrosion resistance and strength. BIOSS4 steel possesses a good combination of high strength and toughness, better corrosion resistance, and better blood compatibility, in comparison with the medical 316L stainless steel. Potential applications of BIOSS4 steel can include medical implantation material and orthodontic or orthopedic devices, as well as jewelries and other decorations.

关键词: medical stainless steel;nitrogen;nickel-free;nickel-allergy;blood;compatibility;austenitic steels;high-nitrogen;corrosion;cells

Nickel-free Stainless Steel for Medical Applications

Yibin REN , Ke YANG , Bingchun ZHANG , Yaqing WANG , Yong LIANG

材料科学技术(英)

BIOSS4 steel is essentially a nickel-free austenitic stainless steel developed by the Institute of Metal Research, Chinese Academy of Sciences, in response to nickel allergy problems associated with nickel-containing stainless steels that are widely used in medical applications. The high nitrogen content of this steel effectively maintains the austenitic stability and also contributes to the high levels of corrosion resistance and strength. BIOSS4 steel possesses a good combination of high strength and toughness, better corrosion resistance, and better blood compatibility, in comparison with the medical 316L stainless steel. Potential applications of BIOSS4 steel can include medical implantation material and orthodontic or orthopedic devices, as well as jewelries and other decorations.

关键词: Medical stainless steel , null , null , null , null

Nickel-free austenitic stainless steels for medical applications

Science and Technology of Advanced Materials

The adverse effects of nickel ions being released into the human body have prompted the development of high-nitrogen nickel-free austenitic stainless steels for medical applications. Nitrogen not only replaces nickel for austenitic structure stability but also much improves steel properties. Here we review the harmful effects associated with nickel in medical stainless steels, the advantages of nitrogen in stainless steels, and emphatically, the development of high-nitrogen nickel-free stainless steels for medical applications. By combining the benefits of stable austenitic structure, high strength and good plasticity, better corrosion and wear resistances, and superior biocompatibility compared to the currently used 316L stainless steel, the newly developed high-nitrogen nickel-free stainless steel is a reliable substitute for the conventional medical stainless steels.

关键词: medical stainless steel;austenitic stainless steel;high-nitrogen;steel;nickel-free;biocompatibility;high-nitrogen steels;in-vitro;mechanical-properties;corrosion;behavior;ion release;metal-ion;fatigue;316l;surface;vivo

STATISTICAL EVALUATION OF CRITICAL INCLUSION FACTOR FOR SECONDARY RECRYSTALLIZATON IN 3%Si STEEL Lecturer,Department of Materials Engineering,Southwestern Jiaotong University,Chengdu 610031,China

LI Shuchen Southwestern Jiaotong University , Chengdu , ChinaCHEN Mengzhe KE Jun University of Science and Technology Beijing , Beijing , China

金属学报(英文版)

On the basis of statistical data of MnS in the conventional 3% Si steel sheeets after various annealing processes,the critical inclusion factor has been evaluated to be 20 mm~(-1).The inhi- bition of MnS to grain growth has been exactly described.

关键词: 3%Si steel , null , null

CORRELATION BETWEEN STRESS COMPONENTS AND STRESS CORROSION CRACKS IN BRASS Lecturer,Department of Materials Physics,University of Science and Technology Beijing,Beijing 100083,China

QIAO Lijie LIU Rui XIAO Jimei University of Science and Technology Beijing , Beijing , China

金属学报(英文版)

The effects of stress components on nucleation sites and propagation directions of stress cor- rosion cracks in brass were investigated with specimens under mode Ⅱ and mode Ⅲ loadings. The results indicated that under mode Ⅱ loading,stress corrosion cracks nucleated on the site with maximum normal stress component and propagated along the plane perpendieular to the maximum normal stress,under mode Ⅲ loading,the stress corrosion crack was not evident on the 45°plane due to the general corrosion in aqueous solution with high NH_4OH concentra- tion,while stress corroded in aqueous solution with low NH_4OH concentration, numerous cracks with spacings of 10—150μm were found on the 45°plane with maximum normal stress and no stress corrosion cracks was observed on the plane with maximum shear stress.

关键词: stress corrosion cracking , null , null , null

Introduction to atmospheric corrosion research in China

Science and Technology of Advanced Materials

In this paper, we introduce the research on atmospheric corrosion in China. We describe the climate characteristics and the classification of atmospheric corrosivity across the whole country. We also describe the rusting evolution under simulated wet/dry cyclic conditions. (C) 2007 NIMS and Elsevier Ltd. All rights reserved.

关键词: atmospheric corrosion;corrosivity;rusting evolution;weathering steels;rust;mechanism;so2;o-3;no2

Evaluation of the Electroslag Remelting Process in Medical Grade of 316LC Stainless Steel

S. Ahmadi

材料科学技术(英)

This study is focused on the effects of electroslag remelting by prefused slag (CaO, Al2O3, and CaF2) on macrostructure and reduction of inclusions in the medical grade of 316LC (316LVM) stainless steel. Analysis of the obtained results indicated that for production of a uniform ingot structure during electroslag remelting, shape and depth of the molten pool should be carefully controlled. High melting rates led to deeper pool depth and interior radial solidification characteristics, while decrease in the melting rates caused more reduction of nonmetallic inclusions. Large shrinkage cavities formed during the conventional casting process in the primary ingots were found to be the cause of the fluctuation in the melting rate, pool depth and extension of equiaxed crystals zone.

关键词: Ultra clean steel , null , null , null , null

Thermally biological effects and its medical functions of the infrared rays absorbed by living systems

International Journal of Infrared and Millimeter Waves

thermally biological effects of infrared lights absorbed have been studied by nonlinear quantum theory and molecular biological theory on the basis of structures of cell and water molecules. There is a large number of water in the living systems, it play an important role in living activity, and has a lot of biological functions. There would be no life without water. We can confirm that the thermally biological effect is a result produced by disorder motions of bio-water-molecules according to the essence of heat, feature of molecular structure of water, theory of molecular physics, principle of resonante absorption and experimental fact that infrared light can heat liquid water. Therefore, mechanism of this effect is that the infrared light absorbed results in the quantum vibrations of water molecules with hydrogen bonds, the vibrational energy again transformes as thermal energy of disorder motions of a great number of water molecules in the living systems. The heating waters can cause a lot of biological effects and phenomena to occur in the living systems. Therefore, the infrared lights absorbed by the living systems have some medical functions.

关键词: infrared light;water;thermally biological effect;vibration;energy-spectra;hydrogen-bond;vibrational-energy-spectra;nonlinear quantum-theory;local-mode;water;h2o;molecule

  • 首页
  • 上一页
  • 1
  • 2
  • 3
  • 4
  • 5
  • 下一页
  • 末页
  • 共33页
  • 跳转 Go

出版年份

刊物分类

相关作者

相关热词