欢迎登录材料期刊网

材料期刊网

高级检索

Three-dimensional finite element flow field model of spraying pipe of roller-type quenching machine is built.The flow field with different structural parameters is computed.After grouping the nozzles,the spraying uniformity is analyzed under the conditions of different water inlet pipe diameter,different water inlet pipe distance,nozzle diameter and nozzle distance.And the spraying intensity absolute deviation and relative deviation are computed under different conditions.The effect of different structural parameters on cooling uniformity is obtained.The results provide theoretical basis for improving production quality and optimizing cooling device design.

参考文献

[1] 邵正伟.中厚板热处理工艺与设备发展趋势[J].轧钢,2006(04):37-39.
[2] HAN Li-xin .On Constructing Heat Treatment Assembly of Medium and Heavy Plate in Jigang[J].Heat Treatment,2003,18(04):22.
[3] ZOU Hong;HAN Xue-hao .Modern Plate Heat Treating Unit and Its Application Effect[J].China Metallurgy,2008,16(04):40.
[4] 唐治宇,杨云清,刘君,王强.湘钢宽厚板热处理区域工艺设备选型探讨[J].宽厚板,2005(04):36-39.
[5] 聂义宏,付书红,惠卫军,傅万堂,刘中华.硼对高强度弹簧钢脱碳敏感性的影响[J].钢铁研究学报,2005(04):45-50.
[6] 朱冬梅,刘国勇,李谋渭,张少军.中厚板冷却过程中热残余应力的控制[J].北京科技大学学报,2008(08):947-951.
[7] 王国栋.均匀化冷却技术与板带材板形控制[J].上海金属,2007(06):1-5.
[8] CAI Jin-biao;SONG Yao-hua .Modern Plate Heat Treating Unit and Its Application Effect[J].Steel Rolling,1997,14(06):3.