An experimental investigation was conducted to identify the characteristics of crack growth in high performance concrete (HPC) subjected to fire, including two parts of work, I.e. Crack growth resistance determinations and cracking observations, using concrete of three strength grades 40 Mpa, 70 Mpa, and 110 Mpa. The crack growth resistance curves (R-curves) of HPC subjected to high temperatures were determined using notched three-point bend beam specimens of 100 mm×100 mm×300 mm. The R-curve (crack growth resistance curve) flattening shows that the crack growth resistance has been significantly reduced by elevated temperature. Concrete with a higher strength grade has a steeper R-curve, with a higher fracture toughness but a shorter critical crack growth. The shorter critical crack growth means that concrete of a higher strength grade has a more brittle behavior. The concrete cracking observations reveal that the consequences of rapid heating are quite different from those of slow heating. For slow heating at a rate of 0.5℃/min, HPC suffered no obvious cracking below 600℃ even if it had a high moisture content. Explosive spalling is an extreme case of the internal cracking driven mainly by vapor pressure. All these results confirmed the vapor pressure mechanism for spalling behavior which should be more significant for denser concrete. The crack growth ranges obtained from the R-curve determination results are in good agreement with those measured in the concrete cracking observations.
参考文献
[1] | PCAitcin.High Performance Concrete[M].E · FN SPON Press, London,1998:591. |
[2] | PKMehta;PCAitcin .[J].Cement,Concrete and Aggregates,1990,12:70. |
[3] | NaiqianFENG.High Performance Concrete China Construction Industry Press[M].北京,1996:406. |
[4] | CCastillo;AJDurrani .[J].ACI Materials Journal,1990,87:47. |
[5] | LTPhan .NISTIR 5934 Building Fire Research Laboratory[Z].National Institute of Stards TechnologyGaitherburg Maryl USA,1996. |
[6] | WMLin;TDLin;LJPowers-Couche .[J].ACI Materials Journal,1996,93:199. |
[7] | PAJahren.Proc of the 3rd Int Conf[M].ACI SP-114DetroitUSA,1989:1013. |
[8] | LKristensen;TCHansen .[J].ACI Materials Journal,1994,91:453. |
[9] | JWDougill .[J].Magazine of Concrete Research,1972,24:71. |
[10] | YNSChan;GFPeng;MAnson .[J].ACI Materials Journal,1999,96:405. |
[11] | KMNemati;PJMMonteiro;NGWCook .[J].Journal of Materials in Civil Engineering,1998,10:128. |
[12] | GFPeng.PhD Thesis The Hong Kong Polytechnic University[M].香港,2000:213. |
[13] | ASTM E 399-90: Standard Test Method for Plane-Strain Fracture Toughness of Metall,Mater[M].American Society of Testing Materials, USA,1990(33) |
[14] | ISO/TR 834-3:1994(E): Fire Resistance Tests-Elements of Building Construction, International Organization for St,ardization, 1994, 11[S].,1994. |
[15] | YNSChan;GFPeng;MAnson .[J].Cement and Concrete Composites,1999,21:23. |
[16] | SPShah .[J].Engineering Fracture Mechanics,1990,35:3. |
[17] | AMNeville.Properties of Concrete Longman Group Limited[M].Harlow Engl,1995:844. |
- 下载量()
- 访问量()
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%