采用非平衡磁控溅射法在血管支架上制备Ti-O薄膜、重点研究了支架表面薄膜厚度、内外表面薄膜差异及两种变形方式下薄膜的力学性能.支架表面积用精密MES电子天平称得质量计算得到,薄膜厚度通过薄膜质量与支架表面积的关系求得;用X-射线电子能谱(EDX)分析了支架内外表面薄膜成份及含量;对支架压缩、撑开并选取变形量大、应力集中单元筋进行研究,用扫描电子显微镜(SEM)观察薄膜是否有破坏.结果表明,在该工艺下支架表面薄膜平均厚度为9.98nm,支架内外表面薄颜色泽均匀,薄膜附着性良好,在支架压缩和撑开过程中,应力大的单元筋表面没有观察到薄膜的开裂、剥落,薄膜的力学性能可靠.

参考文献

[1] Ankur Raval;Animesh Choubey;Chhaya Engineer;Devesh Kothwala .Development and assessment of 316LVM cardiovascular stents[J].Materials Science & Engineering, A. Structural Materials: Properties, Misrostructure and Processing,2004(1/2):331-343.
[2] Maguire P D;McLaughlin J A;Okpalugo T I T.Mechanical stability,corrosion performance and bioresponse of amorphous diamond-like carbon for medical stems and guidewires[J].Diamond and Related Materials,2005(14):1277-1288.
[3] W. Walke;Z. Paszenda;J. Filipiak .Experimental and numerical biomechanical analysis of vascular stent[J].Journal of Materials Processing Technology,2005(0):1263-1268.
[4] Lally C;Dolan F;Prendergast PJ .Cardiovascular stent design and vessel stresses: a finite element analysis[J].Journal of Biomechanics,2005(8):1574-1581.
[5] Marrsk DM .Sufaee Effects on the Growth,Adhesion and properties of Reactively Deposited Hard Coatings[J].Surface and Coatings Technology,1996,81:8-16.
[6] 黄楠;杨萍;陈元儒.[M].成都:西南交通大学出版社,1995:10,59.
[7] 王志浩,冷永祥,孙鸿,黄楠.Ti和TiO2薄膜在血管支架表面附着状况的研究[J].功能材料,2006(10):1660-1662.
[8] De Seheerder I;Verbeken E;Van Humbeeck.Metallic surface modification[J].Seminars in Interventional Cardiology,1998(03):139-144.
[9] Dumoulin C.;Cochelin B. .Mechanical behaviour modelling of balloon-expandable stents[J].Journal of Biomechanics,2000(11):1461-1470.
[10] Tsyganov I;Maitz M F;Wiser E .Correlation between blood compatibility and physical surface properties of titaniumbased coatings[J].Applied Surface Science,2004,235:156-163.
[11] Li CR.;Zhang FM.;Yang SQ.;Wang HM.;Chen LZ.;Zhang F.;Wang XH.;Liu XH.;Zheng ZH. .TiO2-x films prepared by ion beam assisted deposition[J].Nuclear Instruments and Methods in Physics Research, Section B. Beam Interactions with Materials and Atoms,2000(0):21-25.
[12] Wang Xianghui;Zhang Feng;Li Changrong et al.Improvement of blood compatibility of artificial heart valves via titanium oxide film coated on low temperature isotropie carbon[J].Surface and Coatings Technology,2000,129:36-42.
[13] Chua S N D;Macdonald B J;Hashmi M S J .Finite-Element Simulation of Slotted Tube(Stent)with the Presence of Plague and Artery by Balloon Expansion[J].Journal of Materials Processing Technology,2004,155-156:1772-1779.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%