用化学方法、金相显微镜和扫描电镜等对腐蚀减薄失效后的W0714己内酰胺薄膜蒸发器下料管管壁进行了分析,结果表明:此设备用304L不锈钢管壁在非氧化性介质中发生了非敏化态的晶间腐蚀,其腐蚀失效的原因是过钝化电位范围内的电化学溶解所致。
Corrosion mechanism of Tremie pipe of W0714 film evaporator of hexanolactam was investigated by chemical method, optical microscope and SEM etc.. the results showed that the non-sensitive intergranular corrosion took place on the Tremie pipe in the non-oxidizability medium. the potential of 304L SS in the medium was located at the transpassivation region, which resulted in the corrosion of the Tremie pipe.