欢迎登录材料期刊网

材料期刊网

高级检索

利用新型的MICROMEGAS探测器测量了6种不同比例的Ar+CO2混合气体中第一汤逊系数α的两个实验参数A和B。实验结果分析表明,电子在栅极的透过率在75%时,α的测量误差小于13%,而探测器增益的涨落造成的α的测量误差小于8%。

In this paper,the MICROMEGAS detector was employed to measure the experimental parameters A and B of the first Townsend coefficient α in 6 different ratio of Ar+CO2 gas mixtures.The results indicate that the error of α is less than 13% in the condition of electron transmission rate of the mesh up to 75% and is less than 8% due to gain fluctuation of the detector.

参考文献

[1] SauliF. CERN, 77-09,1977, 3, 38.
[2] Sharma A, Sauli F. 1993, January 6, CERN-PPE/93-50.
[3] AUriemma G, Fidanza D, Pirozzi G. et al. Nucl Instr and Meth, 2003, A513: 484.
[4] Mohammad Nakhostin, Mamoru Baba, Tsutomu Ohtsuki, et al. Nucl Instr and Meth, 2007, A572: 999.
[5] Giomataris Y, Rebourgeard Ph, Robert J P, et al. Nuel Instr and Meth, 1996, A376: 29.
[6] Giomataris I, De Oliveira R, Andriamonje S, et al. Nucl Instr and Meth, 2006, A560 405.
[7] 张小东,陈绪涛,张毅,等.高能物理与核物理,2007,31(11):1045.
[8] Tang Haohui, Guo Junjun, Wang Xiaolian, etal. Chinese Physics C, 2009, 33(9) 777.
[9] Fan Ruirui, Hou Fengjie, Ouyang Qun, etal. Chinese Physics C, 2010, 34(10): 1636.
[10] Crowe R W, Bragg J K, Devins J C. J Appl Phys, 1955, 26 : 1121.