地表电位梯度指标容易检测,但根据现有标准难以获得管道杂散干扰腐蚀的有用信息.本文采用新的方法测量电位梯度,并根据测量数据,解析出二种电流成分:地表干扰电流和流入(出)管道的电流;后者和实际杂散干扰腐蚀有良好相关,电流流出管道的位置代表阴极保护管道的腐蚀活性点.
It is easy to inspect the magnitude of potential gradient on the ground surface, but difficult to obtain the useful information about interference corrosion of buried pipelines, based on current standard. In the present paper, a new inspecting method was used for measurement of potential gradient and two components were distinguished from the measured data, namely:interference current on the surface and the current flowing into or out off pipelines. The later has good relation with the practical interference corrosion and where with the current out off denotes the corrosion active location in pipelines cathodically protected (CP).
参考文献
[1] | SY/T0017-06.中华人民共和国石油天然气行业标准,埋地钢质管道直流排流保护技术标准[S].2006. |
[2] | 卢德馨.大学物理学[M].北京,高等教育出版社,1998.306. |
[3] | 翁永基,李英义,李相怡,等.钢电极检测土壤电位梯度的实验研究[J].管道设备与技术,2006,5:34. |
[4] | 翁永基,李英义,李相怡,等.埋地管道直流杂散干扰研究,Ⅰ.检测指标和评价体系.腐蚀科学与防护技术,2010,22(1):1. |
[5] | 郭仿平,何兰.概率论与数理统计[M].北京:机械工业出版社,2005,185. |
[6] | RP0502-2002.Pipeline External Corrosion Direct Assessment Methodology[S].US:2002. |