高级检索

本文介绍了一种新型的阵列式射流冷板,通过一系列实验,分析了该射流冷却型冷板的性能,实验结果表明,该冷板在系统最高温升不超过40℃的条件下,冷却能力超过了400 W/cm2,实验还表明该新型冷板具有局部冷却能力高、等温好等特点,特别适用于高可靠性和等温性要求的阵列式局部高热流密度军用电子器件的冷却.

参考文献

[1] C F Ma .Jet Impingement Heat Transfer with or without Boiling[J].Journal of Thermal Science,1996,5(02):128-131.
[2] Murat Ulasir .Experimental and Numerical Study of Submerged,Round Buoyant Jets Impinging on a Horizontal Surface[D].Michigan:Univisity of Michigan,2001.
[3] AvijitBhunia;Chung-Lung Chen .Liquid Impingement Cooling of High Power Density Silicon Carbide Semiconductor Devices[AIAA 2002-0209[R].,2002.
[4] Evelyn N. Wang;Lian Zhang;Linan Jiang;Jae-Mo Koo;James G. Maveety;Eduardo A. Sanchez .Micromachined Jets for Liquid Impingement Cooling of VLSI Chips[J].Journal of Microelectromechanical Systems: A Joint IEEE and ASME Publication on Microstructures, Microactuators, Microsensors, and Microsystems,2004(5):833-842.
[5] 钱吉裕,平丽浩,徐德好,王长武,宣益民,李强.冲击角对射流强化换热影响的数值研究[J].工程热物理学报,2007(z2):65-68.
[6] 张靖周,李永康,谭晓茗,李立国.阵列射流冲击冷却局部对流换热特性的数值计算与实验研究[J].航空学报,2004(04):339-342.