叙述了γ探测器的14.1 MeV中子灵敏度标定原理和屏蔽方法,利用MCNP程序建模,优化设计了对γ和中子高屏蔽性能的屏蔽体.实验研究表明,其信噪比最高达10:1,比测量点本身的信噪比1.35:1提高了7倍,从而实现了γ探测器的中子灵敏度标定.

参考文献

[1] Hu Mengchun,Ye Wenying,Tang Zhangkui,et al.Nuclear Physics Review,2005,22(1):64(in Chinese).(胡盂春,叶文英,唐章奎等.原子核物理评论,2005,22(1):64.)
[2] Moszynski M,Kapusta M,Wolski D.Nucl Instr and Meth,1998,A404:157.
[3] Belogurov S,Bressi G,Carugno G.Nucl Instr and Meth,2004,A516:58.
[4] Gorin A,Kuroda K,Manuilov I.Nucl Instr and Meth,2003,A510:76.
[5] Baccaro Cecilia A,Montecchi M.Nucl Instr and Meth,1998,A406:479.
[6] Zhang Lianwen,Zhu Shifu,Wang Yongguo,et al.Journal of Synthetic Crystals,2002,31(1):54(in Chinese).(章连文,朱世富,王永国.人工晶体学报,2002,31(1):54.)
[7] Zhang Jianhua,Zhang Chuanfei,Pen Taipn,et al.Atomic Energy Science and Technology,2006,40(4):447(in Chinese).(张建华,张传飞,彭太平等.原子能科学技术,2006,40(4):447.)
[8] Zhang Jianhua,Pen Taipn,Hu Mengchun,et al.Journal of Synthetic Crystals,2006,35(5):1057(in Chinese).(张建华,彭太平,胡孟春等.人工晶体学报,2006,35(5):1057.)
[9] Liu Qinzhao.The Diagnosis Technology of Pulse Radiation Field.Beiing:Scence Press,1994,158.