Dedicated position sensitive gamma-ray detectors based on position sensitive photomultiplier tubes (PSPMTs) coupled to scintillation crystals, have been used for the construction of compact gamma-ray imaging systems, suitable for nuclear medical imaging applications such as small animal imaging and single organ imaging and scintimammography. In this work, the performance of two gamma-ray detectors: a continuous YAP scintillation crystal coupled to a Hamamastu R2486 PSPMT and a pixellated NaI(TI) scintillation array crystal coupled to the same PSPMT, is compared. The results show that the gamma-ray detector based on a pixellated NaI(TI) scintillation array crystal is a promising candidate for nuclear medical imaging applications,since their performance in terms of position linearity, spatial resolution and effective field of view (FOV) is superior than that of the gamma-ray detector based on a continuous YAP scintillation crystal. However, a better photodetector (Hamamatau H8500 Flat Panel PMT, for example) coupled to the continuous crystal is also likely a good selection for nuclear medicine imaging applications.
参考文献
[1] | Garibaldi F;Cisbani E;Cusanno F et al.[J].Nuclear Instruments and Methods in Physics Research A:Accelerators Spectrometers Detectors and Associated Equipment,2001,471:222. |
[2] | Soares A.J.;Cullum I. .Development of a compact wavelength-shifting fibre gamma camera[J].IEEE Transactions on Nuclear Science,2000(3):1058-1064. |
[3] | Paul R;Pellegrini R;Cinti M N et al.[J].Nuclear Instruments and Methods in Physics Research A:Accelerators Spectrometers Detectors and Associated Equipment,2006,569:296. |
[4] | Hamamatsu Photomultiplier Tube Hamamatsu Photonics K.K.Electron Tube Center,Position Sensitive Photomultiplier Tube with Crossed Wire Anodes R2486 Series,Specifications Manual[M].Japanese,1993 |
[5] | Baccaro S.;Denotaristefani F.;Maly P.;Mares JA.;Pani R. Pellegrini R.;Soluri A.;Blazek K. .SCINTILLATION PROPERTIES OF YAP-CE[J].Nuclear Instruments and Methods in Physics Research, Section A. Accelerators, Spectrometers, Detectors and Associated Equipment,1995(1/2):209-215. |
[6] | Pani R.;Scafe R.;Pellegrini R.;Soluri A.;Trotta G.;Indovina L.;Cinti MN.;De Vincentis G. .Scintillation arrays characterization for photon emission imaging[J].Nuclear Instruments and Methods in Physics Research, Section A. Accelerators, Spectrometers, Detectors and Associated Equipment,2002(1/3):72-76. |
[7] | CN/ASD Group.PAW Users Guide,nProgram Library Q121[M].CERN,1993 |
[8] | ZHU Jie;LIU Shi-Tao;LEI Xiao-Wen;YAN Tian-Xin;XU Zi-Zong;WANG Zhao-Min .Study of performance of small gamma camera consisting of crystal pixel array and position sensitive photomultiplier tube[J].Nuclear Science and Techniques,2005(4):238-243. |
[9] | ZENG Hai-Ning;XU Zi-Zhong;WANG Zhao-Min et al.[J].HEP & NP,2000,24(02):165. |
[10] | Giokaris N;Loudos G;Malntas D et al.[J].Nuel Instrum Methods A,2006,569:185. |
[11] | Pard R;Pellegrini R;Betti M et al.[J].Nuclear Instruments and Methods in Physics Research A:Accelerators Spectrometers Detectors and Associated Equipment,2007,571:475. |
- 下载量()
- 访问量()
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%