金属钛及其合金在人体硬组织替换中具有广泛的应用.为改善其表面性能,使其具有表面生物活性,研究发展了多种生物活化方法.包括物理法、化学法和电化学法3大类.本文对钛及钛合金种植体的各种表面活化方法进行了综述.阐述了各种方法进行钛及钛合金表面活化的工艺过程及其活化机理,分别指出了各种方法的优缺点.与物理法相比,化学法具有设备和操作简单、易形成均匀涂层、结构和成分与自然骨相似等优点.对化学法,还需要进一步提高效率,提高涂层与基体之间的结合强度,并对其长期植入效果及其活化机理进行深入研究.
参考文献
[1] | 张玉梅 et al.稀有金属材料与工程[J].,1999,28(02):125. |
[2] | Parakala P;Clegg R;Bell J.6th World Biomaterials Congress[C].Hawaii:Society for Bimaterials,2000:923. |
[3] | Weng W;Baptista J L .[J].Journal of the American Ceramic Society,1999,82(01):27. |
[4] | 俞耀庭;张兴栋.生物医用材料[M].天津:天津大学出版社,2000:131. |
[5] | Zyman Z;Weng J;Liu X .[J].Biomaterials,1993,14:225. |
[6] | Zyman Z;Weng J;Liu X.[J].Biomaterials,1994(15):151. |
[7] | Kweh S W K;Khor K A;Cheang P .[J].BIOMATERIALS,2000,21:1223. |
[8] | Chou L;Marek B;Wagner WR .Effects of hydroxylapatite coating crystallinity on biosolubility, cell attachment efficiency and proliferation in vitro.[J].Biomaterials,1999(10):977-985. |
[9] | Cabrini M.;Rondelli G.;Vicentini B.;Cigada A. .EFFECT OF DIFFERENT SURFACE FINISHING AND OF HYDROXYAPATITE COATINGS ON PASSIVE AND CORROSION CURRENT OF TI6AL4V ALLOY IN SIMULATED PHYSIOLOGICAL SOLUTION[J].Biomaterials,1997(11):783-787. |
[10] | Lind M;Overgaard S;Bunger C;Soballe K .Improved bone anchorage of hydroxypatite coated implants compared with tricalcium-phosphate coated implants in trabecular bone in dogs.[J].Biomaterials,1999(9):803-808. |
[11] | Zheng X;Huang M;Ding C .Bond strength of plasma-sprayed hydroxyapatite/Ti composite coatings.[J].Biomaterials,2000(8):841-849. |
[12] | Chou BY;Chang E .Microstructural characterization of plasma-sprayed hydroxyapatite-10 wt% ZrO2 composite coating on titanium.[J].Biomaterials,1999(19):1823-1832. |
[13] | Wen J.;Chen JY.;Zhang C.;Leng Y. .Chemical gradient in plasma-sprayed HA coatings[J].Biomaterials,2000(13):1339-1343. |
[14] | Choi JM;Kim HE;Lee IS .Ion-beam-assisted deposition (IBAD) of hydroxyapatite coating layer on Ti-based metal substrate.[J].Biomaterials,2000(5):469-473. |
[15] | Wolke JGC.;Degroot K.;Jansen JA.;Vanderwaerden JPCM. .STABILITY OF RADIOFREQUENCY MAGNETRON SPUTTERED CALCIUM PHOSPHATE COATINGS UNDER CYCLICALLY LOADED CONDITIONS[J].Biomaterials,1997(6):483-488. |
[16] | Hulshoff JEC;van Dijk K;van der Waerden JPCM .[J].Journal of Biomedical Materials Research,1996,31:329. |
[17] | Clè ries L;Fern á ndez-Pradas J M;Morenza J L .[J].BIOMATERIALS,2000,21:1861. |
[18] | Hayashi K;Mashima T;Uenoyama K .The effect of hydroxyapatite coating on bony ingrowth into grooved titanium implants.[J].Biomaterials,1999(2):111-119. |
[19] | Pham M T;Matz W;Reuther H;Richter E Steiner G Oswald S .[J].Surface and Coatings Technology,2000,128-129:313. |
[20] | Piveteav L D;Girona M I;Schlapbach L;Barboux P, Boilot J P, Gasser B .[J].Journal of Materials Science:Materials in Medicine,1999,10:161. |
[21] | Piveteau LD;Gasser B;Schlapbach L .Evaluating mechanical adhesion of sol-gel titanium dioxide coatings containing calcium phosphate for metal implant application.[J].Biomaterials,2000(21):2193-2201. |
[22] | Kokubo T.;Kim HM.;Nakamura T.;Miyaji F. .SPONTANEOUS FORMATION OF BONELIKE APATITE LAYER ON CHEMICALLY TREATED TITANIUM METALS[J].Journal of the American Ceramic Society,1996(4):1127-1129. |
[23] | Kim HM;Miyaji F;Kokubo T;Nishiguchi S;Nakamura T .Graded surface structure of bioactive titanium prepared by chemical treatment.[J].Journal of biomedical materials research, Part B. Applied biomaterials,1999(2):100-107. |
[24] | 付涛,李金勇,憨勇,徐可为.碱液处理钛合金表面软复合磷酸钙层[J].稀有金属材料与工程,2003(02):137-140. |
[25] | 付涛,黄平,憨勇,徐可为.碱液处理诱导钛合金基体表面沉积磷灰石层[J].稀有金属材料与工程,2000(03):168-171. |
[26] | Kim H M;Miyaji F;Kokubo T .[J].Journal of Biomedical Materials Research Part B:Applied Biomaterials,1997(38):121. |
[27] | Yan W Q;Nakamura T;Kobayashi M;Kim H M Miyaji F .[J].Journal of Biomedical Materials Research,1997,37:267. |
[28] | Kim H M;Miyaji F;Kokubo T .[J].Journal of Biomedical Materials Research,1996,32:409. |
[29] | Kim H M;Takadama H;Miyaji F .[J].The Korean Journal Ceram,1998,4(04):336. |
[30] | Wen HB.;Dewijn JR.;Liu Q.;Cui FZ.;Degroot K.;Wolke JGC. .FAST PRECIPITATION OF CALCIUM PHOSPHATE LAYERS ON TITANIUM INDUCED BY SIMPLE CHEMICAL TREATMENTS[J].Biomaterials,1997(22):1471-1478. |
[31] | Wen HB;de-Wijn JR;Cui FZ;de-Groot K .Preparation of calcium phosphate coatings on titanium implant materials by simple chemistry.[J].Journal of biomedical materials research, Part B. Applied biomaterials,1998(2):227-236. |
[32] | Tengvall P;Lundstr I;Sjoqvist L;Elwing H Bjursten L M .[J].Biomaterials,1989,10:166. |
[33] | Ohtsuki U;Iida H;Hayakawa S;Osaka A .[J].Journal of Biomedical Materials Research,1997,35:39. |
[34] | Wang X.-X.;Hayakawa S. .Improvement of bioactivity of H_2O_2/TaC1_5-treated titanium after subsequent heat treatments[J].Journal of biomedical materials research, Part B. Applied biomaterials,2000(1):171-176. |
[35] | Bunker B C 等.[J].Science,1994,264:48. |
[36] | Yokogawa Y;Nishizawa K;Nagate F.6th World Biomaterials Congress[C].Hawaii:Society for Biomaterids,2000:1315. |
[37] | Groot K;Wen H B;Liu Y;Layrolle P, Barrere F .[J].Materials Research Society Symposium Proceedings,2000,599:109. |
[38] | Shirkhanzadeh M .[J].Journal of Materials Science:Materials in Medicine,1995,6:90. |
[39] | Ban S;Maruno S .Hydrothermal-electrochemical deposition of hydroxyapatite.[J].Journal of biomedical materials research, Part B. Applied biomaterials,1998(3):387-395. |
[40] | HanY;Xu K;Lu J.[J].Journal of Materials Science:Materials in Medicine,1999(10):243. |
[41] | Chen JS.;Hon MH.;Juang HY. .Calcium phosphate coating on titanium substrate by a modified electrocrystallization process[J].Journal of Materials Science. Materials in Medicine,1998(5):297-300. |
[42] | Wei M;Ruys AJ;Milthorpe BK;Sorrell CC .Solution ripening of hydroxyapatite nanoparticles: effects on electrophoretic deposition.[J].Journal of biomedical materials research, Part B. Applied biomaterials,1999(1):11-19. |
[43] | Gottlander M.;Wennerberg A.;Albrektsson T.;Radin S. Ducheyne P.;Johansson CB. .BONE TISSUE REACTIONS TO AN ELECTROPHORETICALLY APPLIED CALCIUM PHOSPHATE COATING[J].Biomaterials,1997(7):551-557. |
[44] | Dasarathy H;Riley C;Coble H D .[J].Journal of Biomedical Materials Research,1996,31:81. |
[45] | Ishizawa H;Ogino M .Formation and characterization of anodic titanium oxide films containing Ca and P.[J].Journal of biomedical materials research, Part B. Applied biomaterials,1995(1):65-72. |
[46] | Ishizawa H;Ogino M .[J].Journal of Biomedical Materials Research,1995,29:1071. |
[47] | Ishizawa H;Fujino M;Ogino M .[J].Journal of Biomedical Materials Research,1995,29:1459. |
[48] | Buser D;Schenk R K;Steinemann S;Fiorellini J P,Fox C H,Stic H H .[J].Journal of Biomedical Materials Research,1991,25:889. |
[49] | Tini M;Cigada A;Rondelli G;Chiesa R,Giardino R,Giavaresi G,Aidini N N,Torricelli P,Vicertinic B .[J].Biomaterials,1999,20:1587. |
[50] | Takebe J.;Itoh S. .Anodic oxidation and hydrothermal treatment of titanium results in a surface that causes increased attachment and altered cytoskeletal morphology of rat bone marrow stromal cells in vitro[J].Journal of biomedical materials research, Part B. Applied biomaterials,2000(3):398-407. |