高炉内部不同区域的环境存在差异,确定不同冷却壁在高炉内的合适安装位置,以延长冷却壁寿命,同时达到高炉长寿的目的,仍是设计师们应考虑的问题。以高炉炉内温度场为基础,从材料的导热性能、抗热冲击性能和耐磨性能3方面进行分析,提出了风口以上不同区域冷却壁的设计要求,并根据设计要求探讨了铜冷却壁和铸铁冷却壁的布置方式。研究结果表明,炉身中、上部应采用球墨铸铁冷却壁,炉腰、炉腹及炉身下部应采用铜冷却壁。

Circumstances are varying among different parts of inner BF, and for the purpose of BF long campaign, ensuring reasonable installation position of cooling staves in BF for cooling stave life extension is still a considerable problem for designers. On a basis of BF inner temperature field, through the analysis on conductivity, washing resistance and abrasive resistance of materials, design requirements of cooling staves installed on different parts above tuyere was proposed, and according to the design requirements, the arrangement of copper staves and cast iron staves was discussed. The results shows that ductile iron staves should be installed on middle and upper stack, while copper staves should be installed on bosh, belly and lower stack.

参考文献

[1]
[2] 程树森,杨天钧,薛庆国,全强.长寿高炉冷却器布置方式的计算传热学分析.北京科技大学学报.2002(24),2.15-18;
[2]潘国友,杨乃伏,顾飞.高炉煤气和炉料温度场迎风有限元法解析.钢铁.2001(36),1.14-18;
[3] 吴桐,程树森.高炉铜冷却壁合理操作建议.钢铁.2011(36),10:11-15
[4] 乌沙科夫,赫鲁谢娃.球墨铸铁的耐磨性.铸冶.1953,7.30-34;
[5] 张寿荣,于仲洁.武钢高炉长寿技术.冶金工业出版社.2009,7;
[6]钱亮, 程素森. 高炉铜冷却壁自保护能力的实现. 北京科技大学学报. 2006,11(28):1052-1057
[7]Liang Qian, Susen Cheng, Hongbo Zhao.Quantificational Indexes for Design and Evaluation of Copper Staves for Blast Furnaces [J].Journal of University of Science and Technology Beijing, Mineral, Metallurgy, Material, 2008, 2(15):10-16.
[8]Robert G. Helenbrook, Paul.Roy. Water Requirements for Blast Furnace Copper Staves. Iron and Steelmaker. 2000(27),6.166-173;
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%