将非饱和含湿多孔介质层内液体饱和度当量为无量纲的液层厚度,在多孔层内发生相变时其分布规律直观地反映相变传热能力从而预示临界热流(CHF)的发生.计算结果显示,多孔层中心处最容易出现干涸而导致CHF;残余饱和度和孔隙率越大,越不容易出现CHF;饱和度分布形状(液层形状)主要受输入热流密度和孔隙率的影响,热流越小、孔隙率越大就越平缓.
参考文献
[1] | Mughal M P;Plumb O A .An Experimental Study of Boiling on a Wicked Surface[J].International Journal Heat Mass and Transfer,1996,39(04):771-777. |
[2] | M. A. Hanlon;H. B. Ma .Evaporation Heat Transfer in Sintered Porous Media[J].Journal of heat transfer: Transactions of the ASME,2003(4):644-652. |
[3] | Scott G.Liter;Massoud Kaviany .Pool-boiling CHF enhancement by modulated porous-layer coating: theory and experiment[J].International Journal of Heat and Mass Transfer,2001(22):4287-4311. |
[4] | Chen Li;G. P. Peterson;Yaxiong Wang .Evaporation/Boiling in Thin Capillary Wicks (I)-Wick Thickness Effects[J].Journal of heat transfer: Transactions of the ASME,2006(12):1312-1319. |
[5] | Chen Li;G. P. Peterson .Evaporation/Boiling in Thin Capillary Wicks (II) - Effects of Volumetric Porosity and Mesh Size[J].Journal of heat transfer: Transactions of the ASME,2006(12):1320-1328. |
[6] | Udell K S .Heat Transfer in Porous Media Considering Phase Change and Capillarity--the Heat Pipe Effect[J].International Journal Heat Mass and Transfer,1985,28(02):485-495. |