传统电化学检测技术难以深入研究腐蚀的萌生、发展、转移、抑制等过程,而基于扫描探针的电化学检测技术弥补了这一不足.从工作原理和应用现状,简要概述了4种适用于金属/有机涂层体系腐蚀研究的基于扫描探针、具有高空间分辨率的电化学检测技术,分别为扫描电化学显微镜(SECM)、扫描振动电极技术(SVET)、局部电化学阻抗谱(LEIS)、扫描开尔文探针技术(SKP).4种电化学检测技术均利用金属/有机涂层体系电化学的不均一性,通过检测电流、电压或者阻抗等信号,从微观上反映该体系腐蚀的全过程.基于扫描探针的电化学检测技术的发展及应用,能够从微观上解释金属/有机涂层体系腐蚀发生、发展过程及机理.

参考文献

[1] 王晶晶;金晓鸿;任润桃;叶章基.防腐蚀涂料性能的电化学检测方法[J].材料开发与应用,2008(3):61-65.
[2] 邹妍;王佳;郑莹莹.电化学方法研究锈层覆盖下碳钢的腐蚀规律[J].中国腐蚀与防护学报,2011(2):91-96.
[3] 林昌健;李彦;林斌;胡融刚;张敏;卓向东;杜荣归.扫描电化学微探针的发展及其在局部腐蚀研究中的应用[J].电化学,2009(2):121-128.
[4] 曹发和;夏妍;刘文娟;常林荣;张鉴清.SECM基本原理及其在金属腐蚀中的应用[J].电化学,2013(5):393-401.
[5] 骆鸿;魏丹;董超芳;肖葵;李晓刚;林春芳.金属腐蚀微区电化学研究进展(1)扫描电化学显微镜技术[J].腐蚀与防护,2009(7):437-441.
[6] Galvanic coupling between copper and aluminium in a thin-layer cell[J].Corrosion Science: The Journal on Environmental Degradation of Materials and its Control,20103(3):991.
[7] González-García, Y.;Mol, J.M.C.;Muselle, T.;De Graeve, I.;Van Assche, G.;Scheltjens, G.;Van Mele, B.;Terryn, H..SECM study of defect repair in self-healing polymer coatings on metals[J].Electrochemistry communications,20112(2):169-173.
[8] A. Madhankumar;N. Rajendran;T. Nishimura.Influence of Si nanoparticles on the electrochemical behavior of organic coatings on carbon steel in chloride environment[J].Journal of coatings technology and research,20125(5):609-620.
[9] Mark B. Jensen;Matthew J. Peterson;Niteen Jadhav;Victoria J. Gelling.SECM investigation of corrosion inhibition by tungstate-and vanadate-doped polypyrrole/aluminum flake composite coatings on AA2024-T3[J].Progress in Organic Coatings: An International Review Journal,201412 Pt.B(12 Pt.B):2116-2122.
[10] R. Akid;M. Garma.Scanning vibrating reference electrode technique: a calibration study to evaluate the optimum operating parameters for maximum signal detection of point source activity[J].Electrochimica Acta,200417/18(17/18):2871-2879.
[11] 王力伟;王新华;卢琳;李晓刚.有机涂层剥离的微区电化学研究进展[J].腐蚀与防护,2014(2):158-162.
[12] 骆鸿;董超芳;肖葵;李晓刚;魏丹.金属腐蚀微区电化学研究进展(3)扫描振动电极技术[J].腐蚀与防护,2009(9):631-635,640.
[13] SVET method for characterizing anti-corrosion performance of metal-rich coatings[J].Corrosion Science: The Journal on Environmental Degradation of Materials and its Control,20108(8):P.2636.
[14] J.J. Santana;J. Gonzalez-Guzman;J. Izquierdo;S. Gonzalez;R.M. Souto.Sensing electrochemical activity in polymer-coated metals during the early stages of coating degradation by means of the scanning vibrating electrode technique[J].Corrosion Science: The Journal on Environmental Degradation of Materials and its Control,201012(12):3924-3931.
[15] M. Taryba;S. V. Lamaka;D. Snihirova;M. G. S. Ferreira;M. F. Montemor;W. K. Wijting;S. Toews;G. Grundmeier.The combined use of scanning vibrating electrode technique and micro-potentiometry to assess the self-repair processes in defects on "smart" coatings applied to galvanized steel[J].Electrochimica Acta,201112(12):4475-4488.
[16] 骆鸿;肖葵;董超芳;李晓刚;魏丹.金属腐蚀微区电化学研究进展(2)局部电化学阻抗谱[J].腐蚀与防护,2009(8):511-514.
[17] S.R. Taylor.Incentives for using local elecrochemical impedance methods in the investigation of orgnaic coatings[J].Progress in Organic Coatings: An International Review Journal,20011/3(1/3):141-148.
[18] C. Zhong;X. Tang;Y. F. Cheng.Corrosion of steel under the defected coating studied by localized electrochemical impedance spectroscopy[J].Electrochimica Acta,200814(14):4740-4747.
[19] M.C.S.S. Macedo;I.C.P. Margarit-Mattos;F.L. Fragata;J.-B. Jorcin;N. Pebere;O.R. Mattos.Contribution to a better understanding of different behaviour patterns observed with organic coatings evaluated by electrochemical impedance spectroscopy[J].Corrosion Science: The Journal on Environmental Degradation of Materials and its Control,20096(6):1322-1327.
[20] Barranco, V.;Carmona, N.;Galván, J.C.;Grobelny, M.;Kwiatkowski, L.;Villegas, M.A..Electrochemical study of tailored sol-gel thin films as pre-treatment prior to organic coating for AZ91 magnesium alloy[J].Progress in Organic Coatings: An International Review Journal,20104(4):347-355.
[21] Snihirova, D.;Liphardt, L.;Grundmeier, G.;Montemor, F..Electrochemical study of the corrosion inhibition ability of "smart" coatings applied on AA2024[J].Journal of solid state electrochemistry,20138(8):2183-2192.
[22] W. Nabhan;B. Equer;A. Broniatowski.A high-resolution scanning Kelvin probe microscope for contact potential measurements on the 100 nm scale[J].Review of Scientific Instruments,19978(8):3108-3111.
[23] Michael Rohwerder;Florin Turcu.High-resolution Kelvin probe microscopy in corrosion science: Scanning Kelvin probe force microscopy (SKPFM) versus classical scanning Kelvin probe (SKP)[J].Electrochimica Acta,20072(2):290-299.
[24] Reddy B;Sykes JM.Degradation of organic coatings in a corrosive environment: a study by scanning Kelvin probe and scanning acoustic microscope[J].Progress in Organic Coatings: An International Review Journal,20054(4):280-287.
[25] 肖葵;董超芳;魏丹;吴俊升;徐龙娇;李晓刚.扫描Kelvin探针研究破损环氧涂层下碳钢的腐蚀行为[J].北京科技大学学报,2011(8):972-977.
[26] XIAO Kui;DONG Chaofang;ZHANG Xin;WU Junsheng;XU Longjiao;LI Xiaogang.Corrosion of Carbon Steel under Epoxy-varnish Coating Studied by Scanning Kelvin Probe[J].武汉理工大学学报(材料科学版)(英文版),2012(5):825-829.
[27] A. Nazarov;A.-P. Romano;M. Fedel;F. Deflorian;D. Thierry;M.-G. Olivier.Filiform corrosion of electrocoated aluminium alloy: Role of surface pretreatment[J].Corrosion Science: The Journal on Environmental Degradation of Materials and its Control,2012Dec.(Dec.):187-198.
[28] Glover, C. F.;Subramanian, R.;Williams, G..In-Coating Phenyl Phosphonic Acid as an Etch-Primer Corrosion Inhibitor System for Hot Dip Galvanized Steel[J].Journal of the Electrochemical Society,20159(9):C433-C441.