欢迎登录材料期刊网

材料期刊网

高级检索

金属材料因其优良的力学性能和抗疲劳性能,适于作为承力部位的植入材料而用于临床医学领域.人体内环境引起的材料腐蚀等原因影响了金属材料在医学领域中的广泛应用.钽金属以其自身优异的耐腐蚀性和生物相容性等独特优势,越来越受到医疗和材料工作者的广泛关注.综述了钽金属的材料特性及其在不同医疗领域中应用的研究进展.

参考文献

[1] Steinemann S G.Evaluation of biomaterials[M].New York:wiley,1980:1.
[2] Pen D P;Brody A R .Alzheimer's disease:X-ray spectrometric evidence of aluminum accumulation in neurofibrillary tangle-bearing neurons[J].Science,1980,208:297.
[3] Staiger MP;Pietak AM;Huadmai J;Dias G .Magnesium and its alloys as orthopedic biomaterials: A review[J].Biomaterials,2006(9):1728-1734.
[4] Schepers S .The biological action of tantalum oxide[J].Arch Ind Health,1955,12:121.
[5] Werman B S;Rietschel R L .Chronic urticaria from tantalum staples[J].Archives of Dermatology,1981,117:438.
[6] 徐皓,安翎.钽丝环扎内固定治疗髌骨骨折33例分析[J].中国厂矿医学,2003(04):305-306.
[7] 侯东明,陈明哲,李选.冠状动脉内置入自制钽丝支架的实验研究[J].中华心血管病杂志,1998(06):438.
[8] Tsao A K;Roberson J R;Christie M J et al.Biomechanical and clinical evaluations of a porous tantalum implant for the treatment of early-stage osteonecrosis[J].Journal of Bone and Joint Surgery-American Volume,2005,87:22.
[9] Watson P S;Ponde C K;Aroney C N et al.Angiographic follow-up and clinical experience with the flexible tantalum cordis stent[J].Catheterization Cardiovasc Diagnosis,1998,43:168.
[10] Rothman M T;Serruys P W;Grollier G et al.Angiographic and clinical one-year follow-up of the cordis tantalum coil stent in a multicenter international study demonstrating improved restenosis rates when compared to pooled PTCA and BENESTENT-I data:The european antiplatelet stent investigation (EASI)[J].Catheterization cardiovasc Interventions,2001,52:249.
[11] Aldegheri R;Tagl ialavoro G;Berizzi A .The tantalum screw for treating femoral head necrosis rationale and results[J].Strategies Trauma Limb Reconstr,2007,2(2-3):63.
[12] 贾晓钧,张云坤,徐南伟.多孔钽金属棒植入联合髓芯减压治疗早期股骨头坏死[J].中国当代医药,2009(25):145-146.
[13] Liu, G.;Wang, J.;Yang, S.;Xu, W.;Ye, S.;Xia, T. .Effect of a porous tantalum rod on early and intermediate stages of necrosis of the femoral head[J].Biomedical materials,2010(6):065003-1-065003-7.
[14] Oh K J;Pandher D S .A new mode of clinical failure of porous tantalum rod[J].Indian J Orthopaedics,2010,44:464.
[15] Xu M;Peng D .Mesenchymal stem cells cultured on tantalum used in early-stage avascular necrosis of the femoral head.[J].Medical hypotheses,2011(2):199-200.
[16] Sagomonyants KB;Hakim Zargar M;Jhaveri A;Aronow MS;Gronowicz G .Porous tantalum stimulates the proliferation and osteogenesis of osteoblasts from elderly female patients.[J].Journal of orthopaedic research,2011(4):609-616.
[17] 陈坚锋,冯宗权,王全兵.骨小梁钽金属棒微创治疗早期股骨头坏死的临床研究[J].临床医学工程,2009(08):21-24.
[18] 夏天;杨述华 .钽棒支撑用股骨头坏死研究概况[J].国际骨科学杂态,2010,31(01):5.
[19] Zhang Y;Ahn P B;Fitzpatrick D C et al.Interfacial frictional behavior:Cancellous Bone,cortical bone,and a novel porous tantalum biomaterial[J].JOURNAL OF MUSCULOSKELETAL RESEARCH,1999,3:245.
[20] Poggie R A;Cohen R C;Averill R G .Characterization of porous metal.Direct compression molded uhrnwpe junction[J].Transactions of the Orthopedic Research Society,1998,23:777.
[21] Brown T D;Poggie R A;Pedersen D R .Finite element analysis of peri-acetabular components[J].Transactions of the Orthopedic Research Society,1999,24:747.
[22] Litsky A S .Elimination of cup-liner micromotion in acetabular components[J].TRANSACTIONS OF THE SOCIETY FOR BIOMATERIALS,1999,22:600.
[23] Walter WL;Walter WK;O'sullivan M .The pumping of fluid in cementless cups with holes.[J].The Journal of arthroplasty,2004(2):230-234.
[24] Malkani AL;Price MR;Crawford CH 3rd .Acetabular component revision using a porous tantalum biomaterial: a case series.[J].The Journal of arthroplasty,2009(7):1068-1073.
[25] Florio C S;Poggie R A;Sidebotham C et al.Stability characteristics of a cementiess monoblock porous tantalum tibial implant without ancillary fixation[J].Transactions of the Orthopedic Research Society,2004,29:1530.
[26] Stulberg SD .Bone loss in revision total knee arthroplasty: Graft options and adjuncts.[J].The Journal of arthroplasty,2003(3 Suppl.1):48-50.
[27] Howard JL;Kudera J;Lewallen DG;Hanssen AD .Early results of the use of tantalum femoral cones for revision total knee arthroplasty.[J].The Journal of Bone and Joint Surgery. American Volume,2011(5):478-484.
[28] Camera A;Cattaneo G;Tedino R .Use of tantalum trabecular metal in total knee arthroplasty[J].Minerva Ortopedicae Traumatologica,2010,61(03):159.
[29] Meneghini RM;Lewallen DG;Hanssen AD .Use of porous tantalum metaphyseal cones for severe tibial bone loss during revision total knee replacement.[J].The Journal of Bone and Joint Surgery. American Volume,2008(1):78-84.
[30] Yukihide Minoda;Akio Kobayashi;Hiroyoshi Iwaki;Mitsuhiko Ikebuchi;Fumiaki Inori;Kunio Takaoka .Comparison of Bone Mineral Density Between Porous Tantalum and Cemented Tibial Total Knee Arthroplasty Components[J].The Journal of Bone and Joint Surgery. American Volume,2010(3):700-706.
[31] Shimko D A;Shimko V F;Sander E A et al.Effect of porosity on the fluid flow characteristics and mechanical properties of tantalum scaffolds[J].Journal of Biomedical Materials Research Part B:Applied Biomaterials,2005,73B(02):315.
[32] Cai W;Cheng Y;Zheng Y F et al.Biomedical properties of tantalum coatings prepared by multi arc ion-plating[J].Materials Science Forum,2005,475-479:2349.
[33] ChenJ Y;Huang N;Yang P.Behavior of platelet adhesion on tantalum containing Ti-O/Ti-N film synthesized by rnagnetron sputtering deposition[A].四川成都,2002:473.
[34] Chen J Y;Leng Y X;Zhang X et al.Effect of tantalum content of titanium oxide film fabricated by magnetron sputtering on the behavior of cultured human umbilical vein endothelial cells (HUVEC)[J].Nucl Instrum Methods Phys Res Sect B:Beam Interact Mater At,2006,242:26.
[35] Balla VK;Banerjee S;Bose S;Bandyopadhyay A .Direct laser processing of a tantalum coating on titanium for bone replacement structures.[J].Acta biomaterialia,2010(6):2329-2334.
[36] Eriksen S;Gillesberg B;Langmaack L N.Tantalum coated carbon-carbon composite material for surgical implants[A].Minnesota,2005:241.
[37] Li H;Zou X;Woo C;Ding M;Lind M;Bunger C .Experimental lumbar spine fusion with novel tantalum-coated carbon fiber implant.[J].Journal of biomedical materials research, Part B. Applied biomaterials,2007(1):194-200.
[38] Cortecchia E;Pacilli A;Pasquinelli G et al.Biocompatible two-layer tantalum/titania-polymer hybrid coating[J].Biomacromolecules,2010,11:2446.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%