考察了硫酸溶解和氢氟酸溶解两种钛合金的溶解方法.采用氢氟酸溶解试样,钛合金中的Fe和Si均可进行准确检测,而用硫酸溶解钛合金样品时,Si含量不能准确检测.进一步研究了硫酸溶解法中不同溶解温度对测量的影响,发现将电炉温度调至较高时,钛合金溶解速度较快,且对Fe的分析没有影响,因此用硫酸溶解钛合金时选择此种溶解方式进行Fe含量的分析.此外,系统考察了10余种不同牌号钛合金中基体元素和共存元素对Fe、Si分析谱线的光谱干扰情况,并进行了分析谱线的选择.Fe259.940 nm、Fe238.204 nm和Fe239.562 nm三条谱线可作为钛合金中Fe元素的分析线;Si251.611 nm则做为Si元素的分析谱线,但当钛合金中Mo含量大于1%时,制作校准曲线分析Si时需进行Mo元素含量匹配.硫酸溶解法Fe的检出限为0.089μg/mL,氢氟酸溶解法Fe和Si的方法检出限分别为0.016 μg/mL和0.097μg/mL.
参考文献
[1] | 郭剑虹,刘少清.用ICP-AES法测定钛合金中多元素[J].宝钢技术,2001(02):37-39. |
[2] | 谢绍金,赵海燏.ICP-AES测定钛基复合材料中镍、钕和铁的研究[J].光谱实验室,2003(02):234-237. |
[3] | 李志波.ICP-AES法同时测定钛合金中多元素的研究[J].分析测试技术与仪器,2005(03):184-187. |
[4] | 王红锋,董俊明.ICP-AES法测定钛合金中的铝、钒、钼、铁、锆[J].化学分析计量,2004(03):20-21,43. |
[5] | 吴世凯.ICP-AES法同时测定钛合金中八种元素的研究[J].特钢技术,2007(04):38-41. |
[6] | P W J M;Boumans;J J A M Vrakking.Inductively coupled plamas:line widths and shapes detection limits,and spectral interferences,An integrated picture.Plenary lecture[J].Journal of Analytical Atomic Spectrometry,1987(02):513. |
[7] | P W J M Boumans.Mutual spectral interferences of rare earth elements in inductively coupled plasma atomic emission spectrometry.I Rational line selection and correction procedure[J].Pectrochim Acta,1988(43B):173P. |
[8] | P W J M Boumans.Mutual spectral interferences of rare earth elements in inductively coupled plasma atomic emission spectrometry.Ⅱ Approach to the compilation and use of pseudo physically resolved spectral data[J].Pectrochim Acta,1988(43B):1365. |
[9] | P W J M Boumans;J J A M Vrakking.Determination limit including selectivity as a criterion for line selection in trace analysis using inductively coupled plasma-atomic emission spectrometry(ICP-AES)atutorial treatment of a fundamental problem of AES[J].Pectrochim Acta,1987(42B):819. |
[10] | P W J M Boumans;J J A M Vrakking.Line selection in somic emission spectrometry using physically resolved spectra[J].Pectrochim Acta,1988(43B):69. |
[11] | 李帆,冯艳秋.ICP-AES法测定铝合金中钪元素的方法研究[J].光谱学与光谱分析,2003(05):968-971. |