为研究热反射屋顶涂料的冬季能耗水平,对建筑屋顶涂覆太阳热反射涂料后的空调用能进行实测.测试选取重庆某办公楼顶层2间办公室,其朝向、建筑外形、围护结构均相同.结果表明:非空调工况下,热反射屋顶室内空气温度较普通屋顶降低约1.2℃;而相同空调工况下,热反射屋顶比普通屋顶房间空调多耗电能0.014 kWh/(d·m2).
参考文献
[1] | Levinson R;Berdahl P;Akbari H;Miller W;Joedicke I;Reilly J;Suzuki Y;Vondran M .Methods of creating solar-reflective nonwhite surfaces and their application to residential roofing materials[J].Solar Energy Materials and Solar Cells: An International Journal Devoted to Photovoltaic, Photothermal, and Photochemical Solar Energy Conversion,2007(4):304-314. |
[2] | Ronnen Levinson;Paul Berdahl;Asmeret Asefaw Berhe;Hashem Akbari .Effects of soiling and cleaning on the reflectance and solar heat gain of a light-colored roofing membrane[J].Atmospheric environment,2005(40):7807-7824. |
[3] | AKBARI H;KONOPACKI S .Calculating energy-saving potentials from heat-island reduction strategies[J].ENERGY POLICY,2005,33(6):721-756. |
[4] | V. Cheng;E. Ng;B. Givoni .Effect of envelope colour and thermal mass on indoor temperatures in hot humid climate[J].Solar Energy,2005(4):528-534. |
[5] | 徐永祥,李运德,师华,杨振波,冯雍.太阳热反射隔热涂料研究进展[J].涂料工业,2010(01):70-74. |
[6] | Hui Shen;Hongwei Tan;Athanasios Tzempelikos .The effect of reflective coatings on building surface temperatures, indoor environment and energy consumption—An experimental study[J].Energy and buildings,2011(2/3):573-580. |
[7] | 高反射屋顶涂料对建筑能耗的影响[J].材料导报,2012(z1):295-297. |
[8] | JGJ/T 177-2009.公共建筑节能检测标准[S].北京:中国建筑工业出版社,2010. |
[9] | 地面气象观测规范[S].北京:气象出版社,2003. |
[10] | 胡达明,赵士怀,黄夏东,王云新.福建省建筑围护结构隔热性能现场检测方法研究[J].新型建筑材料,2010(10):10-12,26. |
[11] | TANG M F;JIANG L.Analysis on thermal measuring of green roof[J].Journal of Central South University of Technology,2009(z1):150-153. |
[12] | 陆耀庆.实用供热空调设计手册[M].北京:中国建筑工业出版社,2008 |