母排绝缘热收缩管能否在使用过程中长期保持优异的电气和力学性能,与材料的抗老化性能直接相关。以某变电站10 kV和35 kV母排上剥离下来相应运行年限分别为0、1、2、9年和0、4、6年的热缩套管为试样,测试了试样的各项性能,并对该型号热缩套管进行了综合性能评估。结果表明:随着运行年限的增长,两种电压等级的试样的拉伸强度均降低,介电常数和介质损耗增大,交流阻抗变小。长时间的自然老化使热缩套管的绝缘性能大大降低。
It mainly depends on the aging resistance of material whether the heat-shrinkable tube for bus-bar could maintain excellent electrical and mechanical properties during long-term using process. Using the heat-shrinkable tubes peeled from 10 kV and 35 kV switchgear busbar in a substation with the operat-ing period of 0, 1, 2, 9 years and 0, 4, 6 years as samples, their properties were tested, and the compre-hensive properties of the type of heat-shrinkable tube were evaluated. The results show that with the oper-ating period prolonged, the tensile strength of the two samples decreases, the dielectric constant and di-electric loss increase, and the AC impedance decreases. Long-term atmospheric aging make the insulating properties of the heat-shrinkable tube decrease obviously.
参考文献
[1] | 陈羽中.热缩型电力电缆附件的技术与应用[J].绝缘材料,2002(02):34-39. |
[2] | 王宏伟.CIAC(R)母排绝缘热缩套管[J].电力系统装备,2005(10):75. |
[3] | 王永明.热缩绝缘材料防护技术在变电站的应用[J].电网技术,2000(09):10-13. |
[4] | 刘喜军,任继超.MPG母排绝缘热收缩管抗自然老化初探[J].齐齐哈尔大学学报(自然科学版),2000(04):46-48. |
[5] | 王睿,李树忠.聚合物辐射交联热收缩材料研究进展[J].辐射研究与辐射工艺学报,2003(03):161-168. |
[6] | 叶飞.一种有限变形情况下高聚物本构模型[J].科技创新导报,2008(36):21-22. |
[7] | 徐曼,曹晓珑,俞秉莉.纳米SiO2/环氧树脂复合体系性能研究--(Ⅱ)复合材料的介电特性和力学特性[J].高分子材料科学与工程,2005(01):156-159. |
[8] | 赵智大.高电压技术[M].北京:中国电力出版社,1999 |
[9] | 赵孔双.介电谱方法及应用[M].北京:化学工业出版社,2008 |