介绍了CO2循环吸收解吸实验台。采用新型混合有机胺CO2吸收剂,在该实验台上进行了长期稳定运行试验,并应用AMSIM软件进行了系统模拟。结果表明,该实验台可以达到12h以上长时间稳定运行,实现了模拟烟气和吸收剂的稳定循环。由于试验过程中不添加新的吸收剂和水,随着吸收剂循环时间的增加,CO2脱除效率缓慢下降,但500h后仍可达83%。试验运行结果和模拟结果达到了较好的吻合。

A lab pilot plant for CO2 capture was shown. This plant was operated continuously for hundreds of hours using new blended aqueous amine solution, and numerical simulation was adopted for the CO2 capture process using AMSIM software. The results indicated that the long-term stable operation more than 12 hours and simulated flue gas and absorbent stable circulation could be achieved. The CO2 removal efficiency reduced slowly with the time elapse because fresh solvent and water were not maked up. However, it remained at a level of 83% after 500 hours. The simulated results agree to the experiment.

参考文献

[1] 黄斌,许世森,郜时旺,刘练波,陶继业,牛红伟,蔡铭,程健.华能北京热电厂CO2捕集工业试验研究[J].中国电机工程学报,2009(17):14-20.
[2] 方梦祥,张卫风,晏水平,骆仲泱,岑可法.燃煤电厂分离CO2的经济性分析[J].浙江大学学报(工学版),2007(12):2077-2081.
[3] 李英杰,赵长遂,李庆钊,段伦博.作为新型C02吸收剂的乙酸钙循环碳酸化特性[J].中国电机工程学报,2008(08):65-70.
[4] 乔春珍,肖云汉,田文栋,阳绍军.钙基CO2吸收剂的循环特性[J].化工学报,2006(12):2953-2958.