介绍西气东输管道4000km干线检查片埋设试验和自行开发仪器的在线检测情况,根据实测管道交流电位、管道与检查片电偶电流,讨论了沿线交流及直流电干扰程度.探讨在一般干扰强度下,用扣除IR降的管道真实电位评价管道最低阴极保护度的可行性.

The buried coupon tests along the 4000 km East-West Gas Pipeline were described, as well as the in-situ measurements on buried coupons by DIY instrument. According to the measured AC potential of pipeline and the currents of coupons to pipeline, the AC and DC electric interference was analyzed along the whole pipeline, respectively. In additions, the possibility of evaluation of the protective degree of the applied cathodic protection on the pipeline by true potential (minus IR drop) was discussed under generic electric interference.

参考文献

[1] Hanson H R, Smart J. AC corrosion on a pipeline located in an HVAC utility corridor[A]. Corrosion[C]. New Or- leans, 2004: 04209.
[2] ANSI/NACE RP 0104-2004, The Use of Coupons for Ca- thodic Protection Monitoring Applications IS]. Houston, Texas, NACE international, 2004.
[3] DD CEN/15280:2006, Evaluation of A. C. corrosion like- hood of buried pipelines - Application to cathodically pro- tected pipelines [S]. British Standard (BSI), 2006.
[4] 许述剑,翁永基.阴极保护检查片评估苏浙沪管段阴极保护效果[A].首届油气资源国际博士生论坛[C].北京,2007:201.
[5] 陈敬龙,翁永基,李英义.检查片与埋地管道间电偶电流的测量[J].管道技术与设备,2009,(5):19.
[6] 石油行业标准,SYT0032-2000,埋地钢制管道交流排流保护技术标准[S].北京:石油工业出版社,2000.