循环闪蒸中初始液膜具有水平速度,使得循环闪蒸特性与静态闪蒸具有很大的不同.本文设计并搭建了循环闪蒸实验台,研究了在不同主循环流量(400,600,800,1000,1200 L.h-1)、闪蒸腔压力(7.4,12.3,19.9,31.2 kPa)和初始液膜高度(140~250 mm)下纯水循环闪蒸显热转化率随进口过热度的变化规律.实验结果表明,循环闪蒸显热转化率随着进口过热度先减小后增大.在同一过热度条件下,循环闪蒸显热转化率随着闪蒸腔压力的增大而增大,随着初始液膜高度增大而减小,随着主循环流量的增大而略有增大.
参考文献
[1] | K. A. AL-SHAYJI;S. AL-WADYEI;A. ELKAMEL .Modelling and optimization of a multistage flash desalination process[J].Engineering Optimization,2005(6):591-607. |
[2] | A.E.Muthunayagam;K.Ramamurthi;J.R.Paden .Low temperature flash vaporization for desalination[J].Desalination: The International Journal on the Science and Technology of Desalting and Water Purification,2005(1/3):25-32. |
[3] | Mohammad Abutayeh;D. Yogi Goswami .Solar Flash Desalination Under Hydrostatically Sustained Vacuum[J].Journal of Solar Energy Engineering,2009(3):031016-1-031016-7. |
[4] | Patrick Sebastian;Jean Pierre Nadeau .Experiments and modeling of falling jet flash evaporators for vintage treatment[J].International Journal of Thermal Sciences,2002(3):269-280. |
[5] | D. Saury;S. Harmand;M. Siroux .Experimental study of flash evaporation of a water film[J].International Journal of Heat and Mass Transfer,2002(16):3447-3457. |
[6] | Yan Junjie;Zhang Dan;Chong Daotong;Wang Guifang;Li Luning .Experimental study on static/circulatory flash evaporation[J].International Journal of Heat and Mass Transfer,2010(23/24):5528-5535. |