在局部电导探针和单丝电容探针的基础上,提出一种新型局部电容探针,用于测量两相流的局部相含率。静态研究表明,局部电容探针能够测量空气水两相流的局部相含率,测量结果不受导电相电导率变化的影响。从工业蒸馏水变化到饱和食盐水(NaCl的质量分数0—5%),局部电容探针输出结果没有明显变化。电极距离在0-30mm的范围内变化,测量结果变化小于1%。动态实验表明,局部电容探针测量的两相流的局部相含率,能够很好反映流动过程(以弹状流为例),和实验观察结果完全一致。只需要设置简单的阈值大小,就可以得到相含率的大小。

Based on needle-contact conductance probe and single-wire capacitance probe, this paper presents a novel probe, namely needle-contact capacitance probe, to measure local phase fraction in air-water two-phase flows. Compared with the traditional one, needle-contact conductance probe, the new one is more independent of water conductance when the salt content is less than 5%. The amplitude of the output signals, up to 6.4V, is much bigger between high and low levels. For the new probe, the variation of the measured value is less than 1% when the electrode distance is below 30mm. The two electrodes of the probe can be separately placed in order to decrease the disturbance to the flow field. Dynamic experimental results showed that the time traces of phase identification are completely consistent with flow strnctures. The phase fraction can be easily calculated provided a threshold is specified in advance.

参考文献

[1] Zhao DJ;Guo LJ;Hu XW;Zhang XM;Wang X .Experimental study on local characteristics of oil-water dispersed flow in a vertical pipe[J].International Journal of Multiphase Flow,2006(10/11):1254-1268.
[2] 赵冬建,郭烈锦,胡晓玮.油水两相分散流的相界面浓度输运方程研究[J].工程热物理学报,2007(04):615-618.
[3] Hibiki T;Lee TH;Lee JY;Ishii M .Interfacial area concentration in boiling bubbly flow systems[J].Chemical Engineering Science,2006(24):7979-7990.
[4] Tatsuya Hazuku;Tomoji Takamasa;Takashi Hibiki;Mamoru Ishii .Interfacial area concentration in annular two-phase flow[J].International Journal of Heat and Mass Transfer,2007(15/16):2986-2995.
[5] Horst-Michael Prasser .Evolution of interfacial area concentration in a vertical air-water flow measured by wire-mesh sensors[J].Nuclear engineering and design,2007(15/17):1608-1617.
[6] S-F Huang;X-G Zhang;D Wang;Z-H Lin .Water holdup measurement in kerosene-water two-phase flows[J].Measurement Science & Technology,2007(12):3784-3794.
[7] HUANG Shanfang,LU Jun,ZHANG Bingdong,WANG Dong.Phase identification by a novel needle-contact capacitance probe in gas-liquid two-phase flows[J].核技术(英文版),2010(05):316-320.