余热排出实验共获得166组稳态实验数据.数据表明,在本参数范围内,当气温为6~23℃、冷热芯高差11m时,只要风速不小于1.5m/s,即可通过自然循环流动带走堆芯衰变功率.风速、功率和阀门开度的快速变化扰动对系统的稳定运行无大的影响,即系统运行对这些快速小扰动有一定的"容忍性".通过引入系统特征参数建立了分析模型,本文得出含经验系数的自然循环流量等半经验公式.与实验数据比较,98.8%的数据点偏差小于士15%.
参考文献
[1] | Zvirin Y;Jeuck Ⅲ P R;Sullivan C W et al.Experimental and Analytical Investigation of a Nature Circulation System with Parallel Loops[J].Journal of Heat Transfer,1981,103:645-652. |
[2] | Vijayan P K;Mehta S K;Date A W .On the Steady State Performance of Nature Circulation Loops[J].International Journal of Heat and Mass Transfer,1991,34:2219-2230. |
[3] | Ishii M;Katatavka I .Scaling Laws for Thermal-hydraulic System under Single Phase and Two Phase Natural Circulation[J].Nuclear Engineering and Design,1984,81:411-425. |
[4] | 杨世铭.传热学[M].北京:高等教育出版社,1980:150-189. |
[5] | Creveling H F;Depaz J F;Baladi J Y et al.Stability Characteristics of a Single-Phase Free Convection Loop[J].Journal of Fluid Mechanics,1975,67:65-84. |
[6] | Reyes J N.An Analytical Solution for Two-Phase Nature Circulation Flow Estimation[C].IAEA Program of Technical Cooperation,1995:1-6. |