欢迎登录材料期刊网

材料期刊网

高级检索

根据由炉渣完全离子化理論导出的硫分配比公式: (%S)/[%S]=(2.56fs)/(γ_s--)·(∑n_+∑n_-)/(nFeO),在充分引用活度系数的条件下,研究炉渣氧化鉄含量对脫硫的作用。文內采用三种碱度的炉渣进行了計算,結果証明文献內前人对FeO作用四种分歧的評价不是相互矛盾的,而相反地是有內在联系的;它們說明FeO在不同条件下显示不同的作用,而这些不同的作用都可用上列硫分配比公式統一地表示出来。最后,对該公式能否适用于碱性化铁炉及側吹碱性轉炉炉渣,以及对該公式存在的某些缺点和問題进行了討論。

As regards the effect of the iron oxide content of molten slags upon desulphurization in iron- and steelmaking, different conclusions have been given in the literature: (1) pure iron oxide slag has a desulphurizing effect and gives a sulphur-distribution ratio of 3.6 at 1600℃; (2) variation of the iron oxide content of openhearth slags from 3 to 70% has practically no effect upon the sulphur-distribution ratio; (3) with electric furnace (or blast furnace) slags, the less the iron oxide content, the higher the sulphur-distribution ratio; and (4) with less basic slags within a certain range of basicity, increase in the iron oxide content brings about an increase in the sulphur-distribution ratio. In the present paper, through calculations with the help of the sulphur-distribution ratio formula: (%S)/[%S]=2.56fs/γ_s--·(Σn+Σn_-)/n_(FeO) derived from the complete-ionization theory of slag constitution and with the introduction of activity coefficients, it has been shown that the above-mentioned four conclusions are not contradictory against one another, and between them there exists an intimate relation. They simply signify that under different conditions iron oxide exerts different actions, and all these different actions could be amalgamated and generalized under the same formula. On the assumption that SiO_2 is present as SiO_4~(4-)in the slag, the formula is not suitable for application to acid slags, while at the same time the effect of temperature upon the sulphur-distribution ratio needs further investigation. The formula has been used to evaluate the sulphur-distribution ratio of basic cupola and basic side-blown converter slags from data in actual practice, and the following resuits have been obtained: (1) desulphurization in the basic cupola practice has practically reached equilibrium; and (2) in basic side-blown converter practice, owing to the presence of gaseous desulphurization, the sulphur-distribution ratio found in actual practice is less than that calculated from the formula.

参考文献

[1]
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%