本文在充灌率、冷凝温度和初始状态三方面对mLHP系统的稳定性进行分析.研究发现,选择合适的充灌率有利于保证系统稳定运行.较少的充灌最时毛细芯容易缺液而导致系统启动失败,较多的充灌量时系统在低热负荷区易发生波动.过低的冷凝温度对系统稳定性有负面影响,系统容易出现温度波动甚至失稳.而毛细芯内气泡的存在,易导致了mLHP系统出现温度迟滞现象.