模拟研究15—5PH不锈钢在6%FeCl2溶液中浸泡不同时间的初期点蚀规律,采用电化学阻抗测试和扫描Kelvin探针技术研究15—5PH不锈钢初期点蚀过程中的电化学行为。结果表明,随着浸泡时间增长,电化学反应电阻和阻抗模值逐渐减小,EIS谱由一个时间常数逐渐变成两个明显的时间常数.随着腐蚀的不断进行,不锈钢表面阴极区和阳极区不断发生变化,呈现局部腐蚀的特征,表面电位也逐渐升高,阴极区和阳极区变得明显,腐蚀反应处于加速过程。
The initial pitting behavior of 15-5PH stainless steel immersed in 6% FeCl3 solution was investigated by electrochemical impedance spectroscopy (EIS) and scanning Kelvin probe (SKP). The results showed that the electrochemical impedance magnitude and the impedance module declined with the immersion time. One time constant appeared in EIS spectrum first then two time constant as the immersion continued. The SKP results indicated that the anodic and cathodic areas alternated constantly with distinct character of localized corrosion. When the corrosion process continued, the surface potential of 15-5PH stainless steel increased, while anodic and cathodic area distinguished evidently from each other.
参考文献
[1] | 刘振宝,梁剑雄,杨志勇,古立新,张秀丽,孙常亮.碳含量对15-5PH沉淀硬化不锈钢板材的组织与性能的影响[J].航空材料学报,2011(01):7-12. |
[2] | 董超芳,安英辉,李晓刚,生海,肖葵.7A04铝合金在海洋大气环境中初期腐蚀的电化学特性[J].中国有色金属学报,2009(02):346-352. |
[3] | 朱庆振,薛文斌,鲁亮,杜建成,刘贯军,李文芳.(Al2O3-SiO2)sf/AZ91D镁基复合材料微弧氧化膜的制备及电化学阻抗谱分析[J].金属学报,2011(01):74-80. |
[4] | 李迎超,高瑾,李晓刚,董超芳,肖葵.扫描Kelvin探针研究缺陷涂层的膜下腐蚀电化学行为[J].北京科技大学学报,2010(09):1169-1174. |