将改性前后的4N-Mg以及TC4合金对照样植入白兔股骨,术后2, 6, 12 w时任取1只处死,进行X线片检查,血镁浓度测试,并对标本进行SEM观察、EDS分析,以及组织切片光镜观察.结果表明,骨内植入试验中,动物血镁浓度均在正常值范围之内;镁基植入材料显示出较好的骨结合性和骨诱导性,新生骨组织矿化明显,新生骨层上有排列整齐的破骨细胞;改性镁基材料的腐蚀降解速率明显减小.初步表明镁基材料有较好的骨诱导性能,改性对镁基材料腐蚀降解有调控作用.

The 4N-Mg alloys with and without modification and the TC4 alloy were embedded in the thigh bones of rabbits. The slices were tested by X-ray method and the concentrations of Mg~(2+) ion in blood were measured for the died rabbits after operation for 2, 6, and 12 w, respectively. The specimens were analyzed by SEM and EDS, and tissue slices were observed by optical microscope. The vivo results show that the magnesium concentrations in the blood of two groups of animal subjects were in the normal scale. The Mg-based materials have good bone inducement and show the better capability of bonding with bone. The new bone mineralizes obviously on the interface. And on the new bone, the osteoclast cells array orderly. The untreated magnesium-based materials are corroded faster than the treated magnesium-based materials. All results indicate that the Mg-based materials show better biocompatibility and capacity to induce new bone, and the surface modification has an effect to control the corrosion rate of Mg-based biomaterials.

参考文献

[1] 高家诚,乔丽英.镁基可降解硬组织生物材料的研究进展[J].功能材料,2008(05):705-708.
[2] GAO Jia-cheng,WU Sha,QIAO Li-ying,WANG Yong.Corrosion behavior of Mg and Mg-Zn alloys in simulated body fluid[J].中国有色金属学会会刊(英文版),2008(03):588-592.
[3] Muller;Wolf Dieter .[J].Materials Research,2007,10(01):5.
[4] Ren Yibin .[J].Key Engineering Materials,2007,342-343:601.
[5] Song Guangling .[J].Corrosion Science,2007,49:1696.
[6] Liu Chenglong .[J].Journal of Vacuum Science and Technology A:Vacuum Surfaces and Films,2007,25(02):334.
[7] Qiao Liying;Gao Jiacheng;Wang Yong .[J].Materials Science Forum,2007,546-549:459.
[8] Witte Frank .[J].BIOMATERIALS,2007,28:2163.
[9] Liang H;Wan YZ;He F;Huang Y;Xu JD;Li JM;Wang YL;Zhao ZG .Bioactivity of Mg-ion-implanted zirconia and titanium[J].Applied Surface Science: A Journal Devoted to the Properties of Interfaces in Relation to the Synthesis and Behaviour of Materials,2007(6):3326-3333.
[10] Witte F;Kaese V;Haferkamp H;Switzer E;Meyer Lindenberg A;Wirth CJ;Windhagen H .In vivo corrosion of four magnesium alloys and the associated bone response.[J].Biomaterials,2005(17):3557-3563.
[11] Masayuki Okazaki .[J].Journal of Oral Tissue Engin,2004,1(01):31.
[12] Witte F;Ulrich H;Rudert M;Willbold E .Biodegradable magnesium scaffolds: Part 1: appropriate inflammatory response.[J].Journal of biomedical materials research, Part A,2007(3):748-756.
[13] Duygulu O et al.[J].Materials Science Forum,2007,546-549(01):421.
[14] 高家诚,李龙川,王勇,乔丽英.表面改性纯镁的细胞毒性和溶血率[J].稀有金属材料与工程,2005(06):903-906.