根据理论分析和实验验证,提出三种新的检测理地管道直流干扰腐蚀指标,并建立埋地管道直流干扰腐蚀的评价体系.

Current standards in petroleun industry prescribe two ispecting indexes for estimation of DC in-terference corrosion of buried pipelines, namely:excursion of pipe/soil potential and magnitude of poten-tial gradient in surface. These indexes are not well defined and lack of quantitative relationship with inter-ference corrosion, so that the standards are difficult to perform in practices. In present paper, three new in-specting indexes for DC interference corrosion are proposed and the corresponding estimating systems are discussed and created.

参考文献

[1] 陈敬和,何悟忠,李绍忠.抚顺地区管道直流杂散电流干扰腐蚀及防护的探讨[J].管道技术与设备.1999(6):13.
[2] 姜长洪,于婉丽,吴星刚,等.输油管道腐蚀与杂散电流测量[J].管道技术与设备,2004(1):10.
[3] SY/T0017-06,埋地钢质管道直流排流保护技术标准[S].2006.
[4] 翁永基,李英义,李相怡,等.钢电极检测土壤电位梯度的实验研究[J].管道设备与技术,2006(5):34,
[5] 胡士信.阴极保护工程手册[M].北京,化学工业出版社,1999,301.
[6] 卢德馨.大学物理学[M].北京,高等教育出版社,1998.306.
[7] Uhlig H H,Revie R W著,翁永基译.腐蚀与腐蚀控制[M].北京:石油工业出版社,1994.519.
[8] 翁永基,李英义,李相怡,等.埋地管道直流杂散干扰研究,Ⅱ.地表电位梯度检测,腐蚀科学与防所技术,2010,22(2).