欢迎登录材料期刊网

材料期刊网

高级检索

实验研究了密度锁反向启动特性,结果表明:启动流量是影响密度锁反向启动过程的关键因素,启动流量偏离平衡流量较小时,余热排出回路反向流量较小,依靠系统本身具有的自稳定性,将很快建立密度锁内水力平衡关系;而启动流量偏离平衡流量较大时,由于余热排出回路流量较大,较多冷却水进入主回路,导致加热水箱入口温度降低,入口温度的降低对密度锁水力平衡关系的建立具有一定的抑制作用,因此反向启动过程中最好避免这一现象的发生。

Reverse startup characteristics of density that the key factor of reverse startup process is the lock are studied experimentally, and it is shown startup mass flow, when the mass flow is more closer to the equivalent one, the reverse mass flow is smaller in residual heat removal loop, and the hydraulic balance in density lock will be built by self-balance characteristic of the system; While when the mass flow is less closer to the equivalent one, because of the larger mass flow and more cold wanter enters into primary loop, the entrance temperature of heat tank becomes lower which restrains hydraulic balance built in density lock, so the phenomena should be avoided during startup process.

参考文献

[1] 吕襄波,阎昌琪,孙立成.密度锁在反应堆非能动安全中的作用分析[J].核动力工程,2005(06):605-608.
[2] Haga K.;Kukita Y.;Tasaka K. .THE SIMULATION TEST TO START UP THE PIUS-TYPE REACTOR FROM ISOTHERMAL FLUID CONDITION[J].Journal of Nuclear Science and Technology,1995(9):846-854.
[3] 谷海峰,阎昌琪,王升飞,孙福荣.密度锁内水力平衡建立方法的实验研究[J].哈尔滨工程大学学报,2009(11):1234-1238.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%