高级检索

以210 t未加绝热层的无碳新钢包为研究对象,建立数值模拟模型进行计算,并利用实际生产数据进行验证。计算结果显示:新钢包蓄热到第10周期达到热饱和状态;新钢包阶段由于蓄热所造成的钢水最大温降为18.3℃,据此建立了新钢包阶段的钢水温度补偿模型。实际应用结果表明,该温度补偿模型的应用提高了中间包的钢水温度命中率,对炼钢厂的生产具有一定指导意义。

Base on the 210 t new ladle without insulation and carbide,a numerical simulation model was built up and verified by the production data.The results show that the new ladle reach the heat saturating state until the tenth circulation through heat storage which causes the greatest drop of the steel temperature is 18.3 ℃.Hereby the temperature compensating model of the new ladle was set up.Actual application results show that the molten steel temperature hitting rate in tundish is raised after using the temperature compensating model,which has a practical guiding significance for the production in steelmaking workshops.

参考文献

[1] 刘占增,蒋扬虎,郭鸿志.炼钢厂钢包的传热数模研究[J].武钢技术,2007(04):20-24.
[2] 崔建军,张莉,徐宏,廖礼宝.新型钢包整体温度场和应力场三维数值模拟[J].炼钢,2006(05):22-25.
[3] N. K. Nath;K. Mandal;A. K. Singh .Ladle furnace on-line reckoner for prediction and control of steel temperature and composition[J].Ironmaking & Steelmaking: Products and applications,2006(2):140-150.
[4] Janke O V A D .Modelling of Temperature Distribution in Refractory Ladle Lining[J].ISIJ International,2003,43:1185.
[5] 杨治立,朱光俊,常长志.钢包稳态温度场的有限元模拟[J].特殊钢,2007(03):41-43.
[6] 王志刚,李楠,孔建益,李友荣,何平显,陈荣荣.钢包底温度场和应力场数值模拟[J].冶金能源,2004(04):16-19,25.
[7] 黄洪斌,李新健,张忠珣,丁岩峰.钢包温度场的模拟及节能计算[J].武汉科技大学学报(自然科学版),2010(01):28-31.
[8] Taddeo M;Chan W .Analysis of the Relationship Between Shell Temperature and Liquid Steel Temperature Loss on Casting Ladles[J].South East Asia Iron and Steel Institute,2008,37(04):22.
[9] G.M. Mazzaferro;M. Piva;S. P. Ferro .Experimental and numerical analysis of ladle teeming process[J].Ironmaking & Steelmaking: Products and applications,2004(6):503-508.