欢迎登录材料期刊网

材料期刊网

高级检索

某电厂锅炉末级过热器出口导汽管弯头硬度值偏低,为查清原因,对试样进行化学成分分析、常温拉伸试验、高温拉伸试验、硬度测试、金相组织分析。结果表明:该弯头成分符合要求,常温和高温力学特性不符合要求,金相组织不是回火托氏体组织;判定P91弯管热处理工艺控制不严,回火温度偏高,得到回火索氏体组织,导致硬度降低,力学特性变差。

In a certain power plant,exit pipe elbows of final stage of superheater are at lower hardness. In order to find out the reason,chemical composition analysis,mechanical properties test at room temperature and high temperature,hardness test, microstructure observation were carried out. The results show that the composition is eligible,the mechanical properties fall short of request,The microstructures are not tempered troostite. The reasons of lower hardness and worse mechanical properties of P91 elbow are that the heat treatment process isn’t controlled strictly,the tempering temperature is on the high side,which results in tempered sorbite.

参考文献

[1] 李益民,杨百勋,崔雄华,韩传高,尚海军.9%~12%Cr马氏体耐热钢母材及焊缝的硬度控制[J].热力发电,2010(03):57-60,81.
[2] 程志寅,谭宇航,王建乔.P91钢材焊缝硬度值控制要点[J].浙江电力,2008(04):59-61.
[3] 邬澍文,程志寅.P91弯头硬度偏低问题的分析和处理[J].电力设备,2008(11):74-76.
[4] 刘宗昌,李雪峰,计云萍,任慧平.珠光体、贝氏体、马氏体等概念的形成和发展[J].金属热处理,2013(02):15-20.
[5] The T91/P91 Book,Vallourec&Mannesmann Tubes[S].,2002.