This study uses Daya Bay RPCs operating in streamer mode to investigate gas mixtures of at least 50% argon,at most 6% isobutane,and with small amounts of SF6.Isobutane is reduced to 2% without degradation of performance,and SF6 reduces the noise rate and current,as well as the signal size.This study provides quantitative relationships between basic RPC operating parameters and various gas compositions.
参考文献
[1] | Santonico R et al.[J].Nuclear Instruments and Methods in Physics Research A:Accelerators,Spectrometers,Detectors and Associated Equipment,1981,187:377. |
[2] | BABAR .Technical Design Report,SLAC-R-95-457[R].,1995-3. |
[3] | Technical Design Report,KEK Report 95-1[R].,1995-4. |
[4] | Guler M et al.CERN/SPSC 2000-028,SPSC/P318,LNGS P25/2000[R].,2000-7-10. |
[5] | Guler M et al.CERN/SPSC 2001-025,SPSC/M668,LNGS-EXP 30/2001 Add.1/01[R].,2001-8-21. |
[6] | CERN/LHCC 99-22[R].,1999-8-13. |
[7] | CERN/LHCC 97-22[R].,1997-6-5. |
[8] | CERN/LHCC 97-32[R].,1997-12-15. |
[9] | The BESⅢ detector,IHEP-BEPCII-SB-13[R].IHEP,Beijing |
[10] | ZHANC J et al.[J].Nuclear Instruments and Methods in Physics Research A:Accelerators,Spectrometers,Detectors and Associated Equipment,2005,540:102. |
[11] | ZHANG J et al.[J].High Energy Physics and Nuclear Physics,2003,27(07):615. |
[12] | HAN J et al.[J].Nuclear Instruments and Methods in Physics Research A:Accelerators,Spectrometers,Detectors and Associated Equipment,2007,577:552. |
[13] | XIE Y et al.[J].Nuclear Instruments and Methods in Physics Research A:Accelerators,Spectrometers,Detectors and Associated Equipment,2009,599:20. |
[14] | Daya Bay collaboration,arXiv:hep-ex/0701029,2007[Q]. |
[15] | Zhang Q;Wang Y;Zhang J;Cao J;Kwok T;Keung H JY;Chen J;Ma L;Han J;Qian S .An underground cosmic-ray detector made of RPC[J].Nuclear Instruments and Methods in Physics Research, Section A. Accelerators, Spectrometers, Detectors and Associated Equipment,2007(2/3):278-284. |
[16] | Band HR;Bellini F;Covarelli R;Di Marco E;D'Orazio A;Ferroni F;Gioi LL;Lopez L;Polci F .Study of HF production in BaBar Resistive Plate Chambers[J].Nuclear Instruments and Methods in Physics Research, Section A. Accelerators, Spectrometers, Detectors and Associated Equipment,2008(1):33-38. |
[17] | Abe K.;Higuchi I.;Hoshi Y.;Kawamura N.;Mikami Y.;Nagamine T.;Narita S.;Neichi K.;Ueki M.;Yamaga M.;Yamaguchi A.;Yusa Y.;Yuta H.;Handa F. .Performance of glass RPC operated in streamer mode with SF6 gas mixture[J].Nuclear Instruments and Methods in Physics Research, Section A. Accelerators, Spectrometers, Detectors and Associated Equipment,2000(2):397-404. |
[18] | Aielli G.;Camarri P.;Cardarelli R.;Di Ciaccio A.;Di Stante L.;Liberti B.;Paoloni A.;Pastori E.;Santonico R. .SF6 quenched gas mixtures for streamer mode operation of RPCs at very low voltages[J].Nuclear Instruments and Methods in Physics Research, Section A. Accelerators, Spectrometers, Detectors and Associated Equipment,2002(3):137-145. |
[19] | ZHANG J et al.[J].Chinese High Energy Phys Nucl Phys,2003,27(11):1019. |