根据一套10 kW级微型分布式冷热电联产系统(采用燃气内燃机发电,地板辐射采暖,吸附制冷机提供空调制冷)在冬夏两季实验研究获得的数据,从热力学第一及第二定律角度,进行热力学分析,与传统的冷、热、电分产系统进行比较,并对不同评价标准得出的结果展开了进一步的探讨.分析揭示了冷热电联产系统高效节能的原因,得出的相关结论为实验系统的改进以及未来实际应用系统的设计,提供了理论依据.

参考文献

[1] World Alliance of Decentralized Energy[M].,2004
[2] Kari Alanne;Arto Saari .Sustainable small-scale CHP technologies for buildings: the basis for multi-perspective decision-making[J].Renewable & sustainable energy reviews,2004(5):401-431.
[3] R Z Wang;X Q Kong;J Y Wu.Performance Research of A Micro CCHP System with Adsorption Chiller[A].Denver,CO,USA,2005
[4] A Bejan.Advanced Engineering Thermodynamics[M].A Wiley-Interscience Publication,1988
[5] 苏长荪.高等工程热力学[M].北京:高等教育出版社,1987
[6] V. Havelsky .Energetic efficiency of cogeneration systems for combined heat, cold and power production[J].International Journal of Refrigeration,1999(6):479-485.
[7] M.A.Smith;P.C.Few .Domestic-scale combined heat-and-power system incorporating a heat pump: analysis of a prototype plant[J].Applied Energy,2001(3):215-232.
[8] 赵冠春;钱立伦.(火用)分析及其应用[M].北京:高等教育出版社,1984