采用超声电沉积法制备了一种铜薄膜,利用浸泡腐蚀实验、电化学测试、金相显微观察和X射线衍射分析等研究了其显微组织和耐腐蚀性.结果表明:与普通电沉积铜薄膜相比,超声电沉积铜薄膜在20%HNO3溶液中开始冒气泡的时间延迟了近2倍,腐蚀速率明显降低;在3.5%NaCl溶液中自腐蚀电位明显高于普通电沉积铜薄膜,自腐蚀电流不及后者的1/2;超声电沉积铜薄膜,晶粒明显小于普通电沉积试样;(200)晶面取向明显增强,(111)衍射峰值也有所增加,(220)取向则显著减弱;从微观上解释了超声电沉积铜薄膜具有较好耐腐蚀性能的原因.
参考文献
[1] | Hyde M E,Compton R G.How ultrasound influence the eletrodeposinon of metal[J].J.Electroanal Chem,2002,531:19. |
[2] | 沈耀亚,赵德智,许凤军.功率超声在化工领域中的应用现状和发展趋势措施[J].现代化工,2002,20(10):14. |
[3] | Walker R,Walker C T.New explanation for the brightness of electrodeposits produced by ultrasound[J].Ultrosonies,1975,13 (2):79. |
[4] | Kristof P,Pritzker M.Improved copper plating through the use of current pulsing & ultrasonic agitation[J].Plating and Surface Finishing,1998,85(11):237. |
[5] | Chiba A,Wu W C.Ultrasonic agitation effects on the eletrodepesinan of copper from a Cupric-EDTA bath[J].Plating and Surface Finishing,1992,79 (12):62. |
[6] | Jensen J A D,Pocwiardowski P,Persson P O A,et al.Acoustic streaming enhanced electrodeposidon of nickel[J].Chemical Physics Letters,2003,368:732. |