基于Donnan渗析原理,采用阴离子交换膜无电压作用下分离饮用水中Cr(Ⅵ).结果表明,当原水中Cr(Ⅵ)初始浓度为1.0 mg/L,pH值为6.95,补偿溶液NaCl浓度为0.1 mol/L,原水和补偿溶液进水流量均为2.5 mL/min,膜两侧溶液搅拌强度为500 r/min,水温为25℃时,阴离子交换膜对Cr(Ⅵ)的分离去除率为86.4%.采用Na2 SO4作为补偿溶液时,Cr(Ⅵ)的分离去除效果降低.调节原水pH值至11.0时,阴离子交换膜对Cr(Ⅵ)的分离去除率下降至78.9%.提高膜两侧溶液搅拌强度,给体池中Cr(Ⅵ)更容易通过膜迁移分离至受体池中.水温由10℃升高至40℃,给体池中Cr(Ⅵ)剩余质量浓度由0.21 mg/L下降至0.12mg/L.
参考文献
[1] | 陆少鸣,陶光华,王健.饮用水原水突发性铬污染的应急处理研究[J].中国给水排水,2010(11):136-138. |
[2] | 何仕均,赵璇,叶裕才,吴小缓.利用弱碱阴离子交换树脂去除饮用水源中微量铬(Ⅵ)[J].清华大学学报(自然科学版),2002(05):662-664,668. |
[3] | Tor A;Buyukerkek T;Cengeloglu Y et al.Simultaneous recovery of Cr(Ⅲ) and Cr(Ⅵ) from the aqueous phase with ion-exchange membranes[J].DESALINATION,2005,171(03):233-241. |
[4] | 徐铜文.扩散渗析法回收工业酸性废液的研究进展[J].水处理技术,2004(02):63-66. |
[5] | Hichour M;Persin F;Molenat J et al.Fluoride removal from diluted solutions by Donnan dialysis with anion-exchange membranes[J].DESALINATION,1999,122(01):53-62. |
[6] | B.S. Krishna;D.S.R. Murty;B.S.Jai Prakash .Surfactant-modified clay as adsorbent for chromate[J].Applied clay science,2001(1/2):65-71. |
[7] | 徐佩立.边界层及其在传递过程中的应用[M].北京:高等教育出版社,1988:26-32. |
[8] | Anabela D. Fonseca;Joao G. Crespo;Jonas S. Almeida;Maria A. Reis .Drinking water denitrification using a novel ion-exchange membrane bioreactor[J].Environmental Science & Technology: ES&T,2000(8):1557-1562. |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%