长径管作为调相器应用于微型脉冲管制冷机系统时存在阻抗不匹配现象,即调相效果好时,往往脉冲管热端阻抗大小,从而使脉冲管中的压力波幅值小,蓄冷器中损失增大,制冷性能降低;用不同管径和长度的长径管作为调相器时,最低制冷温度产生在阻抗匹配区域或热端阻抗最大的区域;对于本实验中的微型脉冲管制冷机,以长颈管作为调相器时最低制冷温度为107.3 K,低于以单纯的小孔阀作为调相器时所获得的最低制冷温度,但还达不到双向进气的水平.
参考文献
[1] | Radebaugh R.Pulse Tube Cryocoolers for Cooling Infrared Sensors[A].NewYork:Plenum Press,2000:363-379. |
[2] | Kanao K;Watanabe N;Kanazawa Y .A Miniature Pulse Tube Refrigerator for Temperature Below 100 K[J].Cryogenics,1994(34):167-171. |
[3] | Zhu S W;Zhou S L;Yoshimura N.Phase Shift Effect of the Long Neck Tube for the Pulse Tube refrigerator[M].New York: Plenum Press,1997:269-277. |
[4] | GardnerDL;Swift G W.Use of inertance in orifice pulse tube refrigerators[J].Cryogenics,1997(37):117-123. |
[5] | Marquardt E D;Radebaugh R.Pulse Tube Oxygen Liquefier[A].New York:Plenum Press,2000:457-465. |
[6] | Swift G W;Gardner D L;Backhaus S .Acoustic Recovery of Lost Power in Pulse Tube Refrigerators[J].Journal of the Acoustical Society of America,1999,105(02):711-732. |
[7] | 侯宇葵 .高频微型脉冲管制冷机设计方法及调相机理研究[D].中国科学院力学研究所,2002. |
[8] | 侯宇葵,靖葳,巨永林,党海政,周远,梁惊涛.长颈管在微型脉冲管制冷机中的应用[C].中国工程热物理学会工程热力学与能源利用学术会议论文集,2002:365-372. |