通过对国内外各种失超检测方法优缺点的比较,本文选取有源功率检测法来实现超导线圈的失超检测,并针对超导线圈电感值相等和电感值不等两种情况对有源功率失超检测电路进行了改进以及实验验证.结果表明,该失超检测方法能够及时准确的检测到失超信号,为超导线圈的失超保护提供了可靠的前提条件.
This paper choose partial active power detecting method to achieve quench detection of superconducting coils by comparing the advantages and disadvantages of quench detection methods at home and abroad.The improvement of partial active power quench detecting circuit is put forward and the experiment is carried out toward the inductance of superconducting coils is equal and not equal.The result shows that the quench detection method can timely and accurately detect the quench signal and provide the reliable precondition for quench protection of superconducting coils.
参考文献
[1] | 余江,曾建平.超导电力设备失超对电力系统的影响[J].电力自动化设备,2002(04):10-13. |
[2] | 喻小艳,李敬东,唐跃进.超导电力装置失超检测的基础研究[J].中国工程科学,2003(10):73-77. |
[3] | 喻小艳,李敬东,唐跃进,程时杰,潘垣.超导磁储能系统的失超检测及保护综述[J].高压电器,2003(05):47-49. |
[4] | N. Nanato;M. Yanagishita;K. Nakamura .Quench detection of Bi-2223 HTS coil by partial active power detecting method[J].IEEE Transactions on Applied Superconductivity: A Publication of the IEEE Superconductivity Committee,2001(1 Pt.2):2391-2393. |
- 下载量()
- 访问量()
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%