Abstraction:The paper presents a new method of determining Ge in gold alloys by potassium iodate potentiometric titration rather than by traditional distillation separation.The influences of conditions such as the reduction acidity,dosage of sodium hypophosphite and reduction time on the determination of Ge were studied.Comparison was made between the influences of end-point indication for potential method and starch method on accruracy and precision of the analysed results,stability and sensitivity of end-point,selectivity of method and so on.The possibility of reaction in an electrochemical way was discussed.Ge in the alloys such as AuGe12,AuGeNi12-2,AuAgGe18.8-12.5 and AuAgGeNi43.8-6-0.2 was measured,respectively,with the relative standard deviation of 0.10%~0.31% and the recoveries of added standard Ge in sample of 99.40%~100.40% when the reduction acidity was 0.40~0.80 mol/L HC1 and 3.3 mol/L H3PO4,15 g sodium hypophosphite and reduction time 40 min.The new method presented is high accuracy and precision in results,good stability and sensibility in end-point,easy operation and strong selectivity of determination.When it is applied to analyse actual samples,satisfactory results are achieved.
参考文献
[1] | 阳岸恒,谢宏潮.金锗合金在电子工业中的应用[J].贵金属,2007(01):63-66. |
[2] | Sung-Min Choi;Gae-Ho Lee;Jae-Kil Han .Determination of Trace Elements of Ge and P in a Gold Bonding Wire by Inductively Coupled Plasma Atomic Emission Spectrometry[J].Bulletin of the Korean Chemical Society,2008(2):393-397. |
[3] | Liu Pengyu,Li Na,Shao Rongzhen,Liu Bing,Wu Xing.ICP-AES Determination of Germanium in GdSiGe Series Alloys as Magnetic Refrigeration Material[J].稀土学报(英文版),2007(03):377-380. |
[4] | Yuetsu Danzaki;Kazuaki Wagatsuma .Prevention of Ge Volatilization in the Chemical Treatment of Ge-Cr-Al-Ce-Sm Amorphous Alloy for the Determination of Ge by ICP-AES[J].Analytical Sciences: The International Journal of The Japan Society for Analytical Chemistry,2002(7):847-849. |
[5] | GB/T 23523-2009.Determination of germanium content in germanium renewable raw materials[S]. |
[6] | GB/T 23513-2009.Chemical analysis methods for germanium concentrate-Rart 1:Determination of germanium content-Potassium iodate titration[S]. |
[7] | 周建,朱利亚,赵青.锗分析方法的研究进展[J].理化检验:化学分册,2012(01):122-128. |
[8] | LIYA ZHU;KAIZHONG LI;SHIPING ZHOU .Solid Phase Extraction and Graphite Furnace Atomic Absorption Spectrometry for the Determination of Heavy Metal Ions[J].Asian Journal of Chemistry: An International Quarterly Research Journal of Chemistry,2008(6):4433-4442. |
[9] | 朱利亚,赵忆宁,李楷中,杨谅孚,杨光宇,管有祥,金娅秋,安中庆,刘云杰.微波消解-硫酸亚铁电位滴定法测定贵金属合金中金[J].冶金分析,2008(05):14-18. |
[10] | Zhu Liya;Yang Guangyu;Li Kaizhong et al.Application of microwave closed digestion tehnique in the treatment of difficultly dissolved Rh,Ir,powder and their samples[J].Precious Metals,2008,29(01):41-45. |
[11] | HAITAO LIN;ZHU LIYA;ZHANGJIE HUANG .Studies on the Solid Phase Extraction and Spectrophotometric Determination of Palladium with 2-(2-Quinolylazo)-5-Dimethylaminoaniline as Chromogenic Reagent[J].Asian Journal of Chemistry: An International Quarterly Research Journal of Chemistry,2007(2):836-842. |
[12] | Lin H;Huang ZJ;Hu Q;Yang G;Zhang G .Determination of palladium, platinum, and rhodium by HPLC with online column enrichment using 4-carboxylphenyl-thiorhodanine as a precolumn derivatization reagent[J].Journal of analytical chemistry,2007(1):58-62. |
[13] | Practical Chemical Handbook Compilation Groop[M].北京:科学出版社,2001 |
- 下载量()
- 访问量()
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%