介绍离心泵快速启动试验装置和试验方法,对一台出口直径为80 mm的小型管道离心泵进行试验研究,分别测试了试验泵的稳态性能和各项瞬态性能,比较分析了两者的区别.结果显示,启动过程中,离心泵的扬程紧跟转速到达最大值,转速稳定后的瞬态性能与稳态假设对应,流量和扬程的上升历程与管路阻力特性直接相关,而转速与其基本无关;在启动初始阶段,无量纲扬程呈现很大值,继而迅速减小到低于稳态假设值,表现出明显的瞬态效应.
参考文献
[1] | H Tsukamoto;H Ohashi .Transient Characteristics of a Centrifugal Pump During Starting Period[J].Journal of Fluids Engineering,1982,104(01):6-13. |
[2] | H Tsukamoto;S Matsunaga;H Yoneda et al.Transient Characteristics of a Centrifugal Pump During Stopping Period[J].Journal of Fluids Engineering,1986,108(04):392-399. |
[3] | A Thanapandi;R Prasad .A Quasi-Steady Performance Prediction Model for Dynamic Characteristics of a Volute Pump[J].Journal of Power and Energy,1994,208(01):47-58. |
[4] | A Thanapandi;R Prasad .Centrifugal Pump Transient Characteristics and Analysis Using the Method of Characteristics[J].International Journal of Mechanical Sciences,1995,37(01):77-89. |
[5] | P. J. Lefebvre;W. P. Barker .Centrifugal pump performance during transient operation[J].Journal of Fluids Engineering: Transactions of the ASME,1995(1):123-128. |
[6] | 王乐勤,吴大转,郑水英.混流泵瞬态水力性能试验研究[J].流体机械,2003(01):1-3,6. |
[7] | 王乐勤,吴大转,郑水英.混流泵开机过程瞬态水力性能的数值计算[J].流体机械,2004(01):10-13. |
[8] | 王乐勤,吴大转,胡征宇,郑水英.基于键合图法的叶片泵启动特性仿真[J].工程热物理学报,2004(03):417-420. |