实验研究了初始水温、过热度及水位高度对方腔内池水闪蒸瞬态过程的影响,利用可视化方法观察了闪蒸现象变化特点.实验条件为:水位高度40 mm.60 mm、100 mm、150 mm,初始水温50~88℃,过热度3~35℃.实验结果表明:初始水温一定,过热度越大,水温变化越快,闪蒸现象越剧烈;过热度一定,仞始水温变化对水温随时间的变化影响不大;水位高度增加液体温度下降速度减缓,闪蒸结束后液体温度越高.根据对实验数据的分析,拟合得出了瞬态闪蒸过程的特性关联式.
参考文献
[1] | Miyatake O;Fujii T;Tanaka T et al.Flash Evaporation Phenomena of Pool Water[J].Heat Transfer-Jap,1977,6:13-24. |
[2] | Miyatake O;Murakami K;Kawata Y et al.Fundamental Expcriments with Flash Evaporation[J].Heat TransferJap,1973,2:89-100. |
[3] | Peterson R J;Grewal S S .Investigations of Liquid Flashing and Evaporation due to Sudden Depressurization[J].Int J Heat Mass Tradsfer,1984,27(02):301-310. |
[4] | Saury D;Harmand S;Siroux M .Experimental Study of Flash Evaporation[J].International Journal of Heat and Mass Transfer,2002,45:3447-3457. |
[5] | Saury D;Harmand S;Siroux M .Flash Evaporation from a Water Pool:Influencc of the Liquid Height and of the Depressurization Ratc[J].International Journal of Thermal Sciences,2005,44:953-965. |
[6] | Kim J L;Lior N .Some Critical Transitions in Pool Flash Evaporation[J].International Journal of Heat and Mass Transfer,1997,40(10):2363-2372. |
[7] | Moffat R J .Contributions to the Theory of Single-Sample Uncertainty Analysis[J].Journal of Fluids Engineering Trads of the ASME,1982,104(02):250-260. |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%