为了研究结晶器内壁温度的分布,设计了模拟结晶器工作过程的实验装置,并进行了实验.实验结果表明,结晶器内壁温度趋近于冷却水温度.基于实验,推导了结晶器边界等效导热系数.该系数用于解决金属和冷却水之间的传热,即反映结晶器的传热能力.用等效导热系数处理结晶器的边界传热,对包括结晶器在内的连铸凝固进程温度场进行数值模拟既简单又方便,并且计算结果与实验结果符合.还讨论了拉坯速度和冷却水流量对结晶器温度场的影响.
参考文献
[1] | Samarasekera I V;Brimacombe J K .Thermal Field in Continuous Casting Mould[J].Canadian Metallurgical Quarterly,1979,18(01):251-266. |
[2] | 张富强,王军,梁祥远.中薄板坯高拉速连铸结晶器平均热流研究[J].钢铁,2002(12):19-20,64. |
[3] | C.A.M. Pinheiro;I.V. Samarasekera .Mould heat transfer and continuously cast billet quality with mould flux lubrication Part 1 Mould heat transfer[J].Ironmaking & Steelmaking: Products and applications,2000(1):37-54. |
[4] | C. Chow;I. V. Samarasekera;B. N. Walker .High speed continuous casting of steel billets Part 2: Mould heat transfer and mould design[J].Ironmaking & Steelmaking: Products and applications,2002(1):61-69. |
[5] | 张晨,汪钺强,蔡得祥,朱祖民,王文忠.连铸结晶器综合传热系数的定量分析[J].钢铁研究学报,2000(02):21-24. |
[6] | 金俊泽;郑贤淑;郭可(訒) 等.连铸钢坯凝固进程的数值模拟[J].钢铁,1985,20(05):19-27. |
[7] | 金百刚,王强,邓安元,王恩刚,赫冀成,沈利飞,焦迪清.软接触电磁连铸方坯结晶器的传热分析[J].铸造,2004(02):122-125. |