欢迎登录材料期刊网

材料期刊网

高级检索

对济钢中薄板坯连铸机增加浸入式水VI壁厚频繁造成粘结的原因行了分析,主要原因是由于流场的不同分布,在水口周围形成死区,影响了传热,并通过数模进行了验证,提出了改进方案。

The reason for the frequent stick by the increase of SEN wall-thickness in Jigang medium thick slab caster was analyzed. It is because of the flow field in the different distributions and dead zones around SEN which affect the heat transfer. And it was analyzed by numerical simulation and the program was proposed.

参考文献

[1] 张义春,牛永青,刘耀辉,张志克,赵强.邯钢降低CSP连铸机漏钢率的生产实践[J].河北冶金,2009(03):29-31,22.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%