欢迎登录材料期刊网

材料期刊网

高级检索

采用直流金属真空弧源沉积(DC-MVAD)在316L不锈钢基体上沉积合成了Ti-O系薄膜.在Hank's模拟人体液中,对DC-MVAD合成钛氧薄膜进行了开路电位、电化学极化以及电化学阻抗图谱分析,显示合成薄膜可明显改善在人体环境中的耐腐蚀性能.随着合成氧分压的增加,薄膜的耐蚀能力增强.这主要是由于高O/Ti比的钛氧薄膜具有更为稳定的能量状态、低的孔隙率所致.

参考文献

[1] Leng YX.;Huang N.;Yang P.;Chen JY.;Sun H.;Wang J.;Wan GJ.;Tian XB. Fu RKY.;Wang LP.;Chu PK. .Structure and properties of biomedical TiO2 films synthesized by dual plasma deposition[J].Surface & Coatings Technology,2002(1/3):295-300.
[2] Pan J .Corrosion resistance for biomaterial applications of TiO2 films deposited on titanium and stainless steel by ion-beam-assisted sputtering[J].Journal of Biomedical Materials Research,1997,35:309-318.
[3] Gluszek J.;Furman P.;Nitsch K.;Masalski J. .STRUCTURAL AND ELECTROCHEMICAL EXAMINATIONS OF PACVD TIO2 FILMS IN RINGER SOLUTION[J].Biomaterials,1997(11):789-794.
[4] VLADIMIR V. PANIC;ALEKSANDAR B. DEKANSKI;VESNA B. MISKOVIC-STANKOVIC;SLOBODAN K. MILONJIC;BRANISLAV Z. NIKOLIC .The role of titanium oxide concentration profile of titanium oxide of RuO_2-TiO_2 coatings obtained by the sol-gel procedure on its electrochemical behavior[J].Journal of the Serbian Chemical Society,2003(12):979-988.
[5] 史美伦.交流阻抗谱原理及应用[M].北京:国防工业出版社
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%