本文对一台余热驱动的带有水蓄冷器的单吸附器吸附空调系统进行了实验分析,研究了系统的吸附制冷过程和水蓄冷器的作用与影响,并对该吸附制冷系统中的吸附式蓄冷这种无能量损失的蓄冷方式的放冷过程进行了实验分析,比较了蓄冷式系统和双吸附器连续制冷系统的制冷性能及其优缺点.