高级检索

某核电站在运行8 年以后, 高压加热器水室隔板发生腐蚀穿孔. 本文从失效有关的因素如水室结构、水室用材料和水化学等入手, 分析了发生穿孔的原因, 同时采用有限元方法分析流体相关因素, 得出发生失效的原因是流动加速腐蚀.

After 8 years operation, a clapboard in water box of high pressure heater experienced perforation corrosion in a nuclear power plant. The structure, water chemistry and material of the water box are analyzed so that to trace out the mechanism of corrosion failure. In the meanwhile, the finite element method is used to ascertain the factors influencing corrosion failure. At last, the reason for failure is given, which is flow accelerated corrosion.