喷雾相变冷却具有高热流密度的换热能力,本文通过建立喷雾相变冷却实验系统,以液氨为工质,使用单喷嘴,对冷却面为2.5 cm×1.2 cm的热沉进行了实验研究.结果表明:以氨为工质的喷雾相变冷却具有较高的换热能力;在热流密度达到400 W/cm2时,热沉表面的温度在15℃以下;在实验工况不变时,随喷嘴喷淋高度的降低,临界热流密度值(CHF)增大,最大换热系数可达95000 W/(m2·K).
参考文献
[1] | J. Yang;L. C. Chow;M. R. Pais .Nucleate boiling heat transfer in spray cooling[J].Journal of heat transfer: Transactions of the ASME,1996(3):668-671. |
[2] | Daniel P. Rini;Ruey-Hung Chen;Louis C. Chow .Bubble Behavior and Nucleate Boiling Heat Transfer in Saturated FC-72 Spray Cooling[J].Journal of heat transfer: Transactions of the ASME,2002(1):63-72. |
[3] | Milan Visaria;Issam Mudawar .Theoretical and experimental study of the effects of spray inclination on two-phase spray cooling and critical heat flux[J].International Journal of Heat and Mass Transfer,2008(9/10):2398-2410. |
[4] | 芦秋敏,雷树业.雾化喷射冷却的机理及模型研究[J].工程热物理学报,2005(05):817-819. |
[5] | Y. M. Qiao;S. Chandra .Spray cooling enhancement buy addition of a surfactant[J].Journal of heat transfer: Transactions of the ASME,1998(1):92-98. |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%